• OSC UNIT ADJUSTMENT
ADJUSTMENT ITEM
REFERENCE SIGNAL LEVEL • Reference frequency source
ADJUSTMENT CONDITION
: External
4 - 3
OPERATION
1) Connect an SSG to J71, and then set
it as;
• Frequency : 10.00000 MHz
• Modulation : None
• Level
: –10 dBm
2) Connect a 50 ohm terminator to J73.
3) Set the reference level to maximum.
VALUE
L61, L62
(Repeatedly)