Figure 7.1.
Push Air Shutter stem FULLY back to disengage burner from
injector.
Air
Shutter
Head
Injector
Install
Lock
Screw -
LP ONLY
Figure 7.3.
Injector and Pilot conversion. The LP shutter lock screw sets the
minimum shutter opening for propane.
Remove Pilot Shield.
Figure 7.2. Remove Burner.
INSTALLER NOTE:
Pilot Shield is removed for
PROPANE in a Minimum Vent Run.
For taller vent configurations, or
where high winds are present, the
shield can remain installed if nuisance
outages are experienced.
Keep the Pilot Shield for potential
future replacement.
130112_Rev 2 GF 160 DV 2/22