Table Of Contents - Camus Hydronics DynaFlame DFW501 Installation, Operation And Service Manual

Gas fired commercial copper tube boilers
Hide thumbs Also See for DynaFlame DFW501:
Table of Contents

Advertisement

Table of Contents

PART 1 GENERAL INFORMATION ........................................................................................................................... 1
1.0
OVERVIEW ................................................................................................................................................... 1
1.1
INTRODUCTION ........................................................................................................................................... 1
1.2
SPECIAL INSTRUCTIONS TO OWNER ...................................................................................................... 1
1.3
CHECKING EQUIPMENT ............................................................................................................................. 2
1.4
WHAT THE LIGHTS MEAN ON YOUR CAMUS APPLIANCE ..................................................................... 2
1.5
HOW IT OPERATES (SEQUENCE OF OPERATION) ................................................................................. 2
1.5.1
IGNITION PROCESS .................................................................................................................................... 3
1.5.2
HEAT TRANSFER PROCESS ...................................................................................................................... 3
1.5.3
END OF SEQUENCE .................................................................................................................................... 3
1.6
CODES .......................................................................................................................................................... 4
1.7
WARRANTY .................................................................................................................................................. 4
1.8
REMOVAL OF EXISTING APPLIANCE ........................................................................................................ 4
1.9
BOILER ROOM OPERATING CONDITION ................................................................................................. 5
1.10
CLEARANCE FROM COMBUSTIBLE MATERIAL ....................................................................................... 5
1.11
INSTALLATION PROCEDURE LOCATION OF UNIT .................................................................................. 6
PART 2 VENTING ....................................................................................................................................................... 8
2.1
GENERAL VENTING GUIDE ........................................................................................................................ 8
2.1.1
CATEGORY I AND CATEGORY Ill VENTING .............................................................................................. 8
2.1.2
VENTING GUIDELINES FOR CATEGORY I AND/OR III VENTING ........................................................... 9
2.1.3
CATEGORY II AND CATEGORY IV VENTING ............................................................................................ 9
2.1.4
VENTING GUIDELINES FOR CATEGORY II AND/OR IV VENTING .......................................................... 9
2.1.5
APPROVED VENTING MATERIALS ............................................................................................................ 9
2.1.6
VENT TERMINATION CLEARANCES ......................................................................................................... 9
2.1.7
INLET CAP FOR ROOFTOP TERMINATION ............................................................................................ 10
2.1.8
LOCATION OF A ROOFTOP AIR INLET AND VENT CAPS ..................................................................... 10
2.1.9
AIR INLET DAMPER ................................................................................................................................... 10
2.1.10
MASONARY CHIMNEY INSULATIONS ..................................................................................................... 10
2.1.11
VERTICAL VENTING TERMINATION ........................................................................................................ 10
2.1.12
COMBINED COMBUSTION AIR INLET ..................................................................................................... 10
2.1.13
DRAIN TEE ................................................................................................................................................. 11
2.2
CONVENTIONAL VENTING (INDOOR) INSTALLATIONS ........................................................................ 11
2.2.1
AIR REQUIRED FOR COMBUSTION AND VENTILATION ....................................................................... 12
2.2.2
EXHAUST FANS ......................................................................................................................................... 12
2.3
OUTDOOR VENTING ................................................................................................................................. 12
2.4
THRUWALL VENTING ................................................................................................................................ 12
2.4.1
THRUWALL VENT CAP (14-0090) THRUWALL INTAKE AIR CAP (14-0101) .......................................... 12
2.4.2
LOCATION OF A THRUWALL VENT TERMINATION ............................................................................... 13
2.4.3
LOCATION OF A "THRUWALL" AIR INLET CAP....................................................................................... 13
2.4.4
LENGTH OF AIR INLET PIPE .................................................................................................................... 13
PART 3 GAS CONNECTION .................................................................................................................................... 13
3.1
GAS CONNECTION ................................................................................................................................... 13
3.2
GAS PIPING ................................................................................................................................................ 14
3.3
INSTALL PIPING ........................................................................................................................................ 14
3.4
DIFFERENTIAL AIR PRESSURE ............................................................................................................... 14
3.5
GAS MANIFOLD DIFFERENTIAL PRESSURE ADJUSTMENT ............................................................... 14
3.6
CHECKING GAS SUPPLY PRESSURE .................................................................................................... 15
3.7
CHECKING DIFFERENTIAL AIR AND GAS PRESSURES ...................................................................... 15
3.8
GAS TRAIN AND CONTROLS ................................................................................................................... 16
3.9
RATIO GAS VALVE .................................................................................................................................... 16
3.10
VENTING OF GAS VALVES AND PRESSURE SWITCHES ..................................................................... 16
3.11
BURNER ..................................................................................................................................................... 16
PART 4 WATER CONNECTION .............................................................................................................................. 17
4.1
FREEZE PROTECTION .............................................................................................................................. 17
4.2
WARNING REGARDING CHILLED WATER SYSTEMS ........................................................................... 17
4.3
INLET AND OUTLET CONNECTIONS ....................................................................................................... 18
4.4
MINIMUM PIPE SIZE REQUIREMENTS .................................................................................................... 18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents