Electrical Connections; Remote Control - Ariston NEXT OUTDOOR EVO User Manual

Table of Contents

Advertisement

INSTALLATION
WARNING
BEFORE PERFORMING ANY WORK ON
THE APPLIANCE, FIRST DISCONNECT IT
FROM THE ELECTRICAL POWER SUPPLY
USING THE EXTERNAL BIPOLAR SWITCH.

Electrical connections

a thorough check of the electrical system.
The manufacturer is not responsible for any damage
caused by the lack of a suitable earthing system or by the
malfunctioning of the electricity mains supply.
Make sure that the system is able to withstand the
maximum power absorbed by the appliance (this is
indicated on the appliance data plate).
Check that the section of the wires is suitable and is not
less 0,75 mm
2
system if it is to operate correctly.
The power supply cable must be connected to a
230V-50Hz network, where the L-N poles and the earth
connection are all respected.
If the supply cord is damaged, it must be replaced by a
special cord or assembly available from the manufacturer
or its service agent.
400
Important!
Connection to the electricity mains supply must
a mobile plug) and a bipolar switch that provide
full disconnection under overvoltage category III
conditions.
The use of multiplugs, extension leads or adaptors is
strictly prohibited.
It is strictly forbidden to use the piping from the hydraulic,
heating and gas systems for the appliance earthing
connection.
The appliance is not protected against the effects caused
by lightning. If the mains fuses need to be replaced, use
2A rapid fuses.
16
/
80
H05VV-F
L

Remote control

The appliance is supplied with a Remote Control and the
corresponding connection cable (30 m).
Positioning the Remote Control
Make sure that:
-
the remote control cannot be accessed by children
-
it is NOT installed near sources of heat
-
it is NOT installed in areas which could become wet
(spraying).
Separate
the wall in the chosen area, using the screws supplied
with the appliance.
If necessary, cut the cable supplied to the desired length
and apply the connectors supplied in the package to
ensure power is supplied properly and safely.
Remote Control connection
Proceed as follows:
-
disconnect the appliance from the electricity supply by
switching the external bipolar switch to OFF.
-
remove the casing as indicated in par. "Instructions for
opening the casing and performing internal inspection".
-
insert the cable into the appliance, via cable gland L.
L
B
F
-
connect the cable to the P.C.B. – see electrical diagram
on following page.
C
D
G

Advertisement

Table of Contents
loading

Table of Contents