Step: Configuring The Drive With Simocomu - Siemens SIMATIC S7-300 Getting Started

Automation systems, controlling a physical axis
Hide thumbs Also See for SIMATIC S7-300:
Table of Contents

Advertisement

Learning units

3.10 9. Step: Configuring the drive with SimoComU

Step
Activity
4
In the SIMATIC Manager, select the Options > Set PG/PC
interface menu command in order to change the MPI
transmission rate to 1.5 Mbit/s.
5
Select the MPI interface. Click the properties and then
change the transmission speed and confirm all open dialog
boxes with "OK".
6
In the left half of the SIMATIC Manager window, select the
SIMATIC 300(1) > CPU 317T-2 DP > S7-Programm >
Blocks entry.
7
Select the Target system > Load menu command in order to
load the blocks and the system data to the CPU.
8
Confirm the message box
Download system data
Overwrite existing system data
3.10
9. Step: Configuring the drive with SimoComU
Procedure
Step
Activity
1
Connect SIMODRIVE 611U to the serial interface of your
PG/PC.
2
Run SimoCom U.
Result: The dialog box shown below opens:
Click "Search for online drives".
Result: SimoCom U automatically searches for the connected drive.
The configuration is opened.
26
Result
The system data blocks are downloaded to
the CPU. The initial download of your SDBs
may take longer (up to a few minutes),
because of their larger data volume.
Result
CPU 317T-2 DP: Controlling a physical axis
Getting Started, 03/2008, A5E00251786-05