Installation - Empire Comfort Systems DVCT36CBP Installation Instructions Manual

Direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

Rough Opening for Floor Level Installation
Rough Opening for Elevated Installation
MODEL
DVCT36CFP
51 1/2
DVCT40CFP
53 1/2
Page 18

INSTALLATION

B
Figure 28
B
Figure 29
INSTALLATION TAbLE - MINIMUM DIMENSIONS (in inches)
A
b
45 1/2
49 1/2
A
Rough Opening for Installing in Corner
The fireplace can be mounted on any of the following surfaces:
1.
A flat, hard combustible or non-combustible surface.
2.
A raised wooden platform.
3.
Four corner supports. (example: Four concrete masonry
blocks.) These supports must be positioned so they contact
all four perimeter edges on the bottom of the fireplace, if
A
allowed by local codes.
NOTICE: Verify the gas supply and electrical considerations
before beginning the framing.
Framing Information
Fireplace framing can be built before or after the fireplace is set
in place. Position framing to accommodate wall covering and
fireplace facing material. Construct the fireplace framing with
2 x 4 lumber or heavier. Refer to the INSTALLATION TAbLE
below for minimum framing dimensions.
Before construction begins, measure fireplace dimensions
and verify framing methods and wall covering details.
C
22 1/8
54 11/16
24
59 11/16
Figure 30
CAUTION
D
E
77-3/8
84-3/8
F
38 11/16
42 1/4
38745-4-0319