16. Rotate the focusing ring in one direction, and stop at accurately
360 degree (1 revolution) rotated positions.
Note: Do not rotate in the reverse direction at the halfway.
Focusing ring
17. "Rotate Ring STOP" is displayed, press the ENTER key.
18. "LENS DEVICE (FOCUS RING) CHECK OK" is displayed,
press the ENTER key.
19. When the ENTER key is pressed, recording the adjustment data
and releasing from adjustment mode are performed automatically,
and "FINISHED" is displayed when the process is completed,
then click the [OK] button.
(2) Flange Back (S)
• Adjust the flange back of inner focus lens.
Subject
Operation on Lens side
Shooting Mode of the camera P mode (Program Auto)
Preparation
Attach the FB adjustment chart to the flange back adjustment jig, and
set the flange back adjustment jig as shown in the following figure.
Flange back
adjustment jig

Adjusting Method

1. Click the [Flange Back (S)] button in the Adjustment and Inspec-
tion.
2. The START screen is displayed, after the preparation of adjust-
ment is completed, press the ENTER key.
3. "ZOOM - WIDE" is displayed, set the zooming ring to the WIDE
end (focal length: 12 mm).
Zooming ring
4. When the ENTER key is pressed, automatic adjustment of WIDE
end is started.
5-27
SEL1224G
Flange back adjustment jig
+ FB adjustment chart
• Zooming ring
Within 10 mm
Zoom: WIDE end
Lens to be tested