5. After the mechanical end adjustment is completed, message
screen is displayed in the following. Set the zooming ring to the
WIDE end (focal length: 12 mm).
Zooming ring
6. When the ENTER key is pressed, message screen is displayed
in the following. Set the zooming ring to the TELE end (focal
length: 24 mm).
Zooming ring
7. "Rotate Ring START" is displayed, press the ENTER key.
8. Rotate the focusing ring more than 1 revolution.
Focusing ring
9. "Rotate Ring STOP" is displayed, press the ENTER key.
10. "Rotate Ring START" is displayed, press the ENTER key.
11. Rotate the focusing ring more than 1 revolution.
Focusing ring
12. "Rotate Ring STOP" is displayed, press the ENTER key.
13. After the focusing ring adjustment is completed, message screen
is displayed in the following.
14. Set for the focusing ring to the position of the tape etc. stuck by
"Preparations".
15. "Rotate Ring START" is displayed, press the ENTER key.
5-26