Remote Condenser Location - Scotsman Prodigy ELITE A Series Installation And User Manual

Remote condenser modular cube
Hide thumbs Also See for Prodigy ELITE A Series:
Table of Contents

Advertisement

MC0530 through MC1030
Remote Cooled User Manual

Remote Condenser Location

Use the following for planning the placement of the
condenser relative to the ice machine
Location Limits - condenser location must not exceed
ANY of the following limits:
Maximum rise from the ice machine to the
condenser is 35 physical feet
Maximum drop from the ice machine to the
condenser is 15 physical feet
Physical line set maximum length is 100 feet.
Calculated line set length maximum is 150.
Calculation Formula:
Drop = dd x 6.6 (dd = distance in feet)
Rise = rd x 1.7 (rd = distance in feet)
Horizontal Run = hd x 1 (hd = distance in feet)
Calculation: Drop(s) + Rise(s) + Horizontal Run =
dd+rd+hd = Calculated Line Length
Configurations that do NOT meet these requirements
must receive prior written authorization from
Scotsman.
Max 35'
hd
Max 15'
rd
Do NOT:
Route a line set that rises, then falls, then rises.
Route a line set that falls, then rises, then falls.
Calculation Example 1:
The condenser is to be located 5 feet below the ice
machine and then 20 feet away horizontally.
5 feet x 6.6 = 33. 33 + 20 = 53. This location would be
acceptable
Calculation Example 2:
The condenser is to be located 35 feet above and
then 100 feet away horizontally. 35 x 1.7 = 59.5.
59.5 +100 = 159.5. 159.5 is greater than the 150
maximum and is NOT acceptable.
Operating a machine with an unacceptable
configuration is misuse and will void the warranty.
dd
40.35"
Remote Condenser Located
ABOVE Ice Machine
Remote Condenser Located
BELOW Ice Machine
June 2022
Page 8
Condenser Distance &
Location Schematic