Download Print this page

Procedure To Remove Four Way Valve - Daikin RZQ100KV4A Removal Procedure

4/5/6 hp class

Advertisement

Procedure to Remove Four Way Valve

7. Procedure to Remove Four Way Valve
Procedure
Step
Recover the refrigerant.
According to the
procedure for the removal
related to the outside
panel, remove the front
panel (2) and the side
panel.
According to the
procedure to remove
switch box, remove the
switch box.
Unscrew the 1 screw
1
that fixes the four way
valve coil, and then
remove this coil.
Remove brazing from
2
the 4 places, and then
remove the four way
valve.
(Refer to point column.)
8
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Be sure to remove the four
way valve only after the
refrigerant is completely
recovered.
Brazing
Four way
valve
Four way
valve coil
To prevent the four way
Brazing
valve from exceeding a
Screw
temperature of 120°C,
conduct brazing work while
cooling the valve with wet
cloths or else.
Si281316