Daikin R24LV2S Service Manual Removal Procedure page 8

6.0 kw class, 24000/28000 class, outdoor unit, non-inverter, pair type

Advertisement

Removal of Outdoor Fan / Fan Motor
Step
4
Remove the nut and
remove the outdoor fan.
5
Remove the 4 screws
and remove the fan
motor.
6
Procedure
Nut
Lock washer
Points
Nut size: M8
When reassembling, fit the
D-cuts of the lock washer
and the shaft of fan motor.
(R15404)
D-cut
Lock washer
Be sure to remove the lower
screws first. If the upper
screws are removed first, the
fan motor may tilt or fall
because the center of its
gravity is toward the front.
It may cause injuries.
Screw size : M5 × 16
(R5439)
Removal Procedure
Si011196
13 mm
(R17450)
(R12834)
D-cut
(R12835)

Advertisement