Split unit air conditioner
ceiling mounted c series; e series; fl-e series; fh-c series; fly-e series; fhy-c series
cooling only & heatpump [50hz] (78 pages)
Page 1
INSTALLATION MANUAL Split System air conditioners R200F7W1 R250F7W1 RY200F7W1 RY250F7W1...
Page 2
fiˆ˜ ÚÔÛ‰ÈÔÚ›˙ÂÙ·È ÛÙÔ ∞Ú¯Â›Ô ∆¯ÓÈ΋˜ ∫·Ù·Û΢‹˜ DAIKIN.TCF.004 Î·È ÎÚ›ÓÂÙ·È ıÂÙÈο ·fi ÙÔ KEMA Û‡Ìʈӷ Ì ÙÔ ¶ÈÛÙÔÔÈËÙÈÎfi 59277-KRQ/ECM95-4233. Nota tal como estabelecido no Ficheiro Técnico de Construção DAIKIN.TCF.004 e com o parecer positivo de KEMA de acordo com o Certificado 59277-KRQ/ECM95-4233. Bemærk som anført i den Tekniske Konstruktionsfil DAIKIN.TCF.004 og positivt vurderet af KEMA i henhold til Certifikat 59277-KRQ/ECM95-4233.
Page 3
H ≤ 1500 ⇒ A ≥ 500 h ≤ 500 ⇒ B1 ≥ 300 H = 1500+X ⇒ A ≥ 500+X/2 h = 500+Y ⇒ B1 ≥ 300+Y/2 ≥20 ≥20 ≥10 ≥10 ≥10 ≥10 (mm) H ≤ 1500 ⇒ A ≥ 500 h ≤...
COULD RESULT IN ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE SPECIFICALLY DESIGNED FOR USE WITH THE EQUIPMENT AND HAVE THEM INSTALLED BY A PROFESSIONAL. IF UNSURE OF INSTALLATION PROCEDURES OR USE, ALWAYS CONTACT YOUR Fragile, handle the unit with care.
4. The space around the unit is adequate for servicing and the Allowable pipe length minimum space for air inlet and air outlet is available. (Refer to figure 1 and choose one of both possibilities.) pair twin/triple double twin 5. There is no danger of fire due to leakage of flammable gas. 50 m 6.
Page 6
OW TO OPEN STOP VALVES EFER TO FIGURE Note front connection To open Make sure to close the piping intake hole again after installation work. 1. Remove the cap (1) and turn the shaft (2) counter-clockwise with hexagon socket screw keys (JIS B 4648 nominal size 6 mm Note bottom connection and 10 mm).
HARGING REFRIGERANT IELD WIRING The cooling only unit does not require any additional charging of refrigerant. The heatpump unit however, requires additional charging of All field wiring and components must be installed by a licensed refrigerant according to the length of pipe connected at the site. electrician and must comply with relevant local and national Take the following steps for proper charging.
NTERNAL WIRING PARTS TABLE IRING OF POWER SUPPLY AND THE UNITS Refer to the wiring diagram on the unit. Refer to the installation manual supplied with the indoor unit for wiring of indoor units. The abbreviations used are listed below. Install an earth leak detector and fuse in the power supply line.