Removal of Electrical Component ASSY
Step
2. Remove the electrical
component ASSY.
1
Disconnect the 2
terminals from the fan
motor capacitor (C2R).
2
Detach the outdoor
temperature sensor.
3
Disconnect the
terminals of the outdoor
temperature thermostat
(S1T).
8
Procedure
Fan motor capacitor (C2R)
White
Red
Outdoor
temperature
thermostat
(S1T)
to X1A: black
to X1A: orange
H
to K1M(4): white
(R16368)
Outdoor
temperature
sensor
(R12813)
(R12814)
(R16369)
L
C
S1T
(R15472)
Si011196
Points
(R17451)
Remove the sensor fixing
plate.