Specifications - Emerson Rosemount 3100 Series Reference Manual

Ultrasonic liquid level transmitters
Hide thumbs Also See for Rosemount 3100 Series:
Table of Contents

Advertisement

Reference Manual
00809-0100-4840, Rev. BA
July 2008
Appendix A

SPECIFICATIONS

General
Product
Measurement principle
Measuring performance
Measurement range
Level resolution
Level accuracy
Blanking distance (Dead Zone)
Update interval
Display / Configuration
Integral Display
Output Units
Output Variables
Configuration tools
Materials of construction
Wet-side material
Body and cover material
Cover seal
Cover screws
Transducer body seal
www.rosemount.com
Reference Data
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-1
Temperature and Pressure Ratings . . . . . . . . . . . . . . . . . page A-3
Load Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-3
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-4
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-6
Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-9
Rosemount 3100 Series liquid level transmitters:
Rosemount 3101: Level and Distance measurement.
Rosemount 3102: Level, Distance, Volume, Open channel flow measurement, two integral signal relays.
Rosemount 3105: Level, Distance, Volume, Open channel flow measurement for hazardous locations.
Ultrasonic, time-of-flight.
Rosemount 3101: 1 to 26 ft (0,3 to 8 m)
Rosemount 3102: 1 to 36 ft (0,3 to 11 m)
Rosemount 3105: 1 to 36 ft (0,3 to 11 m)
1
Better than
/
in. (1 mm)
16
The 3101:
± 0.2 in. (5 mm) for <3.3 ft (1 m),
± 0.5% of measured distance for > 3.3 ft (1 m)
The 3102 and The 3105: ± 0.1 in. (2.5 mm) <3.3 ft (1 m),
±0.25% of measured distance for > 3.3 ft (1 m)
under reference conditions
12 in.(0,3 m)
1 second
4/5 digit display for live measurement, and for configuration purposes.
For Level or distance-to-surface: m, ft, in, or none
3
3
For Contents: l, m
, gal, or ft
3
For Flow: l/s, l/m, m
/hr, gal/s, gal/m, ft
Rosemount 3101: Level, or distance-to-surface
Rosemount 3102: Level (or distance-to-surface), Content (Volume), and Flow.
Rosemount 3105: Level (or distance-to-surface), Content (Volume), and Flow.
Standard integral push-buttons with LCD.
375 Field Communicator.
Rosemount 3490 Series Universal Control Unit.
Rosemount AMS
Suite
PVDF.
Polyurethane-covered Aluminum.
Silicone rubber.
316 Stainless Steel.
EPDM.
Rosemount 3100 Series
(1)
3
3
/m (cfm), ft
/hr, or none

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 3101Rosemount 3102Rosemount 3105

Table of Contents