5 Operational Modes

A6V11144326
Operation modes are selectable only for points, not for devices. They affect how
the points operate in relation to cardholders and the system.
Type
Mode
Door
Card Only
Reader
Card and PIN
Host Verification – Card
only
Host Verification – Card
and PIN
View Only – Card only
View Only – Card and PIN
Double/Single Arming
Card Only Delayed
Reporting
Card And PIN Delayed
Reporting
Disabled Mode
Operational Modes
Description
A card must be presented at the access point to
gain valid access.
A card must be presented AND a matching PIN
entered at the access point to gain valid access.
A card must be presented at the access point to
gain valid access; also, verification is required
by an operator that the live cardholder image
matches the stored database image.
A card must be presented AND a matching PIN
entered at the access point to gain valid access;
also verification is required by an operator that
the live cardholder image matches the stored
database image.
A card must be presented at the access point to
gain valid access; also, a snapshot of the
cardholder is taken as they enter and stored in
the database.
A card must be presented AND a matching PIN
entered at the access point to gain valid access;
also, a snapshot of the cardholder is taken as
they enter, and stored in the database.
A card must be presented at the access point
by a valid cardholder. A double card badge will
arm the area and a single card badge will
disarm operation for all assigned intrusion
areas.
This mode is used for access points for entry or
exit from defined Anti-Passback Areas.
A card must be presented at the access point to
gain valid access or exit from the Area, but
cardholder entry will not be recognized in the
Audit Trail unless the door monitor registers that
the door has opened and closed.
This means that Area counts will not increase or
decrease unless the door monitor registers the
appropriate events.
This mode is used for access points used for
entry or exit from defined Anti-Passback Areas.
A card must be presented at the access point
AND a valid PIN entered to gain valid access or
exit from the Area, but card-holder entry will not
be recog-nised in the Audit Trail unless the door
monitor registers that the door has opened and
closed.
This means that Area counts will not increase or
decrease unless the door monitor registers the
appropriate events.
The access point will be disabled.