Remove the priming pump.
Replace Bleed Screw 85 and Bonded Seal 84.
Connect air supply to tool and switch ON/OFF valve 70 to 'ON" position.
Check that the stroke of the tool meets the minimum specification of 30 millimetres. To check the stroke, measure the
distance between the rear of the tail jaw cylinder and body mouldings, BEFORE pressing the trigger and when the
trigger is fully actuated. The stroke is the difference between the two measurements. If it does not meet the minimum
specification, repeat the priming procedure.
Item numbers in bold refer to the general assembly drawing and parts list on pages 19-20.