Port Isolate - Planet Networking & Communication IGS-5225-8T2S2X User Manual

Table of Contents

Advertisement

That is, although the VLAN 2 members: Port-1 to Port-3 and VLAN 3 members: Port-4 to Port-6 also belongs to VLAN 1. But
with different PVID settings, packets form VLAN 2 or VLAN 3 is not able to access to the other VLAN.
6.
Repeat Steps 1 to 6, set up the VLAN Trunk port at the partner switch and add more VLANs to join the VLAN trunk, repeat
Steps 1 to 3 to assign the Trunk port to the VLANs.

4.3.3.8.3 Port Isolate

The diagram shows how the Industrial Managed Switch handles isolated and promiscuous ports, and the each PC is not able
to access the isolated port of each other's PCs. But they all need to access with the same server/AP/Printer. This section will
show you how to configure the port for the server – that could be accessed by each isolated port.
Setup steps
1.
Assign Port Mode
Set Port-1~Port-4 in Isolate port.
Set Port5 and Port-6 in Promiscuous port. The screen in
Figure 4-3-3-15
Figure 4-3-3-15: The Configuration of Isolated and Promiscuous Port
156
User's Manual of IGS-5225-8T2S2X & 8P2S2X series
appears.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Igs-5225 seriesIgs-5225-8p2s2x

Table of Contents