Lista Sensitivity Detection - Panasonic AG-DVC30P Service Manual

Digital video camera recorder / xlr microphone adapter, mini dv
Table of Contents

Advertisement

1-8. LISTA Sensitivity Detection

In case of use VFK1409A
TP
F2 : ATF-ERR (VFK1409A), TP2 : TRG/HSW (VFK1409A), GND : GND (VFK1409A)
In case of use VFK1409S
F2 : ATF-ERR (VFK1409S), TP2 : TRG/HSW (VFK1810), GND : GND (VFK1409S)
PLAY
VTR MODE
Refer to below explanation
ADJ. MODE
VFM3000EDS (DV LISTA)
TAPE
40 mV /
SPEC.
1. Set the camera recorder to VCR mode.
2. Insert the DV Alignment Tape (VFM3000EDS) to the camera recorder.
3. Press the MENU button to open the "VCR FUNCTION MENU".
4. Open the "8. ADJUST MENU" in "VCR FUNCTION MENU".
5. Select the item "ATF GAIN" and press the MULTI-DIAL.
6. Message "NOW SERVO ADJUST PUSH MENU TO RETURN" appears on screen and press the PLAY button
to playback the tape.
7. Press MENU button to return to "ADJUST MENU" screen.
8. Select item "<1> Sensitivity Measurement" on the LISTA main menu, and press "ENTER".
9. Then the tape is played back (tape speed : 101.2%) automatically, and message "1.2% Speed..." appears on
the screen.
10. Press the ENTER key, and then start measurement of the sensitivity value.
11. Confirm that the sensitivity value is with in specification, after the message "<<Sensitivity Measurement
Finish>>".
Sensitivity
Sens.1
Sens.1
µ
µ
m to 120 mV /
m
<<Sensitivity Measurement Finish>>
72.95 (mV/um)
65.43 (mV/um)
85.48 (mV/um)
Select at Sensitivity Detection.
Confirm that the value of Sens.Value1
and Sens.Value2 in specification
Figure 9