5-2-3. Adjustment item for Video Level

Y LEVEL
Y level of AV OUT and S-VIDEO OUTPUT signal can be adjusted on this item.
The displayed value is the same as value for Luminance level adjustment in EVR adjustment.
C LEVEL
C level of AV OUT and S-VIDEO OUTPUT signal can be adjusted on this item.
The displayed value is the same as value for Chroma level adjustment in EVR adjustment.

5-2-4. Hour Meter Reset and LOG Clear(Only VCR mode)

The Hour Meter and Auto Off Log data can be reset by items on page 2 in Adjust menu screen. To shift page 2
screen, connect the EVR tools and set VTR_TEST SW of the measurement board to L position follow the item
"5-2-1. Connection of EVR Tools".
THREADING RESET
It resets the threading number of times.
TAPE RUN RESET
It resets tape running time.
CYLINDER RESET
It resets cylinder rotating time.
< How to reset Hour Meter >
1. The following message is displayed when choosing the item to reset with MULTI-DIAL and pushing MULTI-DIAL.
(In case select the item CYLINDER)
2. Select YES and when pushing MULTI-DIAL, reset is executed and the following message is displayed.
CYLINDER RESET
EXECUTE ?
NO
PUSH JOG
YES
CYLINDER RESET
INITIAL
COMPLETED !