1-9. LISTA Linearity Adjustment
In case of use VFK1409A
TP
F2 : ATF-ERR (VFK1409A), TP2 : TRG/HSW (VFK1409A), GND : GND (VFK1409A)
In case of use VFK1409S
F2 : ATF-ERR (VFK1409S), TP2 : TRG/HSW (VFK1810), GND : GND (VFK1409S)
S1 and T1 Post Height
ADJ.
PLAY
VTR MODE
Refer to below explanation
ADJ. MODE
VFM3000EDS (DV LISTA)
TAPE
VFK1899 : Post Driver
TOOL
Linearity : less than 3
SPEC.
1.
Set the camera recorder to VCR mode.
2.
Insert the DV Alignment Tape (VFM3000EDS) to the camera recorder.
3.
Press the MENU button to open the "VCR FUNCTION MENU".
4.
Open the "8. ADJUST MENU" in "VCR FUNCTION MENU".
5.
Select the item "LINEARITY" and press the MULTI-DIAL.
6.
Message "NOW SERVO ADJUST PUSH MENU TO RETURN" is appears on screen and press the PLAY
button to playback the tape.
7.
Press MENU button to return to "ADJUST MENU" screen.
8.
Select item "<2> Linearity Measurement" on the LISTA main menu, and press "ENTER", then the Linearity
Waveform appears.
9.
When the waveform as shown in figure below is displayed on the screen, press the "BS (Back Space)" key
for display the waveform positioned at the center of the scale on screen. Adjust S1 and T1 post height by
using the post driver so that the linearity waveform is becomes flat as possible, and it should be within
specification.
(Adjust linearity waveform in the red dot line on the screen.)
µ
m
MECH-9
Select at Linearity Measurement.