Daikin APGM3 Service And Troubleshooting page 50

13.4 seer2 & 15.2 gas-electric package units with r-410a refrigerant
Table of Contents

Advertisement

BLOWER PERFORMANCE DATA
Down Flow
External
Speed
Static
Tap
Pressure
(ESP), in w.c.
0.2
0.4
T1
0.6
0.8
0.2
0.4
T2
0.6
0.8
0.2
0.4
T3
0.6
0.8
0.2
0.4
T4
0.6
0.8
0.2
0.4
T5
0.6
0.8
Shaded area indicates air flow below 1500 SCFM (300 SCFM/ton) that
is not recommended for High Stage cooling or heating
Models: APGM56014041
Standard Static Drive
Burners High Fire Input: 135,000 BTU/HR
SCFM
RPM
983
570
833
659
703
739
574
808
1175
640
1057
714
902
801
790
874
1963
883
1858
939
1760
990
1668
1038
1963
883
1858
939
1760
990
1668
1038
2369
2196
2248
987
2144
1024
2054
1070
5 Ton
Speed
BHP
Tap
(ESP), in w.c.
0.14
0.16
T1
0.18
0.19
0.20
0.22
T2
0.25
0.27
0.66
0.70
T3
0.74
0.77
0.66
0.70
T4
0.74
0.77
2.09
0.94
T5
0.97
1.02
Horizontal Flow
External
Static
SCFM
Pressure
1003
0.2
850
0.4
0.6
718
0.8
586
0.2
1229
1105
0.4
945
0.6
0.8
844
0.2
2032
0.4
1941
1850
0.6
1757
0.8
0.2
2032
0.4
1941
0.6
1850
1757
0.8
2323
0.2
0.4
2245
0.6
2161
0.8
2080
RPM
BHP
606
0.14
701
0.17
785
0.19
858
0.20
617
0.19
699
0.22
795
0.24
861
0.27
853
0.63
908
0.67
966
0.72
1018
0.76
853
0.63
908
0.67
966
0.72
1018
0.76
929
0.88
978
0.93
1028
0.98
1079
1.03
50

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gpgm3Apgm5Gpgm5

Table of Contents