Daikin APGM3 Service And Troubleshooting page 48

13.4 seer2 & 15.2 gas-electric package units with r-410a refrigerant
Table of Contents

Advertisement

BLOWER PERFORMANCE DATA
APGM5** CFM OUTPUT AND DIP SWITCH SETTINGS
MODEL
APGM52406041**
APGM53008041**
APGM53608041**
APGM54210041**
APGM54810041**
x = Not recommended for heating application
DIP Switch Settings
for Single and Two-Stage Thermostats
SWITCH
MODEL
3
N/A
APGM5**
N/A
for DIP Switches 1 -2 / Heating
SPEED
Switch
Switch
TAP
1
A
OFF
B
ON
C
OFF
D
ON
A
OFF
B
ON
C
OFF
D
ON
A
OFF
B
ON
C
OFF
D
ON
A
OFF
B
ON
C
OFF
D
ON
A
OFF
B
ON
C
OFF
D
ON
SWITCH
THERMOSTAT
4
ON
Single Stage
OFF
Two-Stage
CFM Output
Low
High
Heat
Heat
2
CFM
CFM
OFF
600
800
OFF
675
900
ON
735
980
ON
X
OFF
800
1065
OFF
900
1195
ON
1000
1330
ON
X
OFF
800
1065
OFF
900
1195
ON
1000
1330
ON
X
OFF
1015
1350
OFF
1125
1495
ON
1250
1665
ON
X
OFF
1015
1350
OFF
1125
1495
ON
1250
1665
ON
X
CFM Output
for DIP Switches 5 - 6 / Cooling
Switch
Switch
5
6
OFF
OFF
ON
OFF
OFF
ON
X
ON
ON
OFF
OFF
ON
OFF
OFF
ON
X
ON
ON
OFF
OFF
ON
OFF
OFF
ON
X
ON
ON
OFF
OFF
ON
OFF
OFF
ON
X
ON
ON
OFF
OFF
ON
OFF
OFF
ON
X
ON
ON
Adjustments Through Dip Switch
Combinations 7-8
SWITCH
CFM
7
+10%
ON
Normal
OFF
-10%
OFF
Low
High Cool
Cool
CFM
CFM
565
750
600
800
620
825
640
850
605
900
670
1000
720
1075
735
1100
755
1125
805
1200
840
1250
890
1325
1080
1300
1160
1400
1205
1450
1245
1500
1275
1450
1320
1500
1365
1550
1410
1600
SWITCH
8
OFF
OFF
ON
48