Daikin APGM3 Service And Troubleshooting page 44

13.4 seer2 & 15.2 gas-electric package units with r-410a refrigerant
Table of Contents

Advertisement

BLOWER PERFORMANCE DATA
T1 HEATING SPEED
E.S.P.
CFM
WATTS
0.1
745
76
0.2
690
84
0.3
635
91
0.4
570
98
0.5
505
107
0.6
450
115
0.7
395
118
0.8
345
126
T1 HEATING SPEED
E.S.P.
CFM
WATTS
0.1
745
76
0.2
690
84
0.3
635
91
0.4
570
98
0.5
505
107
0.6
450
115
0.7
395
118
0.8
345
126
T1 HEATING SPEED
E.S.P.
CFM
WATTS
0.1
745
76
0.2
690
84
0.3
635
91
0.4
570
98
0.5
505
107
0.6
450
115
0.7
395
118
0.8
345
126
T1 HEATING SPEED
E.S.P.
CFM
WATTS
0.1
1,055
156
0.2
1,000
166
0.3
940
173
0.4
880
181
0.5
825
189
0.6
760
204
0.7
705
207
0.8
625
210
T1 HEATING SPEED
E.S.P.
CFM
WATTS
0.1
1,055
156
0.2
1,000
166
0.3
940
173
0.4
880
181
0.5
825
189
0.6
760
204
0.7
705
207
0.8
625
210
X= Heating Temperature Rise Not Recommended.
A/GPGM33604041** - Rise Range: 25° - 55°
T2 HEATING SPEED
RISE
CFM
WATTS
41
1,115
206
45
1,075
215
48
1,030
221
54
985
233
X
940
234
X
895
242
X
845
248
X
785
252
A/GPGM33606041 - Rise Range: 30° - 60°
T2 HEATING SPEED
RISE
CFM
WATTS
X
1,115
206
X
1,075
215
X
1,030
221
X
985
233
X
940
234
X
895
242
X
845
248
X
785
252
A/GPGM336080M41 - Rise Range: 30° - 60°
T2 HEATING SPEED
RISE
CFM
WATTS
X
1,115
206
X
1,075
215
X
1,030
221
X
985
233
X
940
234
X
895
242
X
845
248
X
785
252
A/GPGM34206041 - Rise Range: 30° - 60°
T2 HEATING SPEED
RISE
CFM
WATTS
44
1,380
298
46
1,320
312
49
1,270
318
52
1,220
327
56
1,160
336
X
1,115
342
X
1,060
347
X
1,000
361
A/GPGM34208041 - Rise Range: 30° - 60°
T2 HEATING SPEED
RISE
CFM
WATTS
58
1,380
298
X
1,320
312
X
1,270
318
X
1,220
327
X
1,160
336
X
1,115
342
X
1,060
347
X
1,000
361
T3 HEATING SPEED
RISE
CFM
WATTS
28
1,265
285
29
1,230
290
30
1,175
300
31
1,140
303
33
1,100
311
34
1,055
319
36
1,010
326
39
960
335
T3 HEATING SPEED
RISE
CFM
WATTS
41
1,265
285
43
1,230
290
45
1,175
300
47
1,140
303
49
1,100
311
52
1,055
319
55
1,010
326
59
960
335
T3 HEATING SPEED
RISE
CFM
WATTS
55
1,265
285
57
1,230
290
60
1,175
300
X
1,140
303
X
1,100
311
X
1,055
319
X
1,010
326
X
960
335
T3 HEATING SPEED
RISE
CFM
WATTS
33
1,415
327
35
1,360
335
36
1,305
343
38
1,260
353
40
1,200
359
41
1,150
371
44
1,110
375
46
1,060
381
T3 HEATING SPEED
RISE
CFM
WATTS
45
1,415
327
47
1,360
335
48
1,305
343
50
1,260
353
53
1,200
359
55
1,150
371
58
1,110
375
X
1,060
381
T4 COOLING
SPEED
RISE
CFM
WATTS
X
1,448
342
X
1,403
343
26
1,358
354
27
1,319
361
28
1,277
366
29
1,232
376
30
1,176
386
32
1,120
395
T4 COOLING
SPEED
RISE
CFM
WATTS
36
1,448
342
37
1,403
343
39
1,358
354
40
1,319
361
42
1,277
366
44
1,232
376
46
1,176
386
48
1,120
395
T4 COOLING
SPEED
RISE
CFM
WATTS
49
1,448
342
50
1,403
343
52
1,358
354
54
1,319
361
56
1,277
366
58
1,232
376
X
1,176
386
X
1,120
395
T4 COOLING
SPEED
RISE
CFM
WATTS
33
1,542
392
34
1,494
403
35
1,437
409
37
1,392
419
38
1,342
430
40
1,295
440
42
1,238
447
44
1,183
454
T4 COOLING
RISE
CFM
WATTS
43
1,542
392
45
1,494
403
47
1,437
409
49
1,392
419
51
1,342
430
53
1,295
440
55
1,238
447
58
1,183
454
T5 COOLING
SPEED
CFM
WATTS
1,440
426
1,390
428
1,365
440
1,335
440
1,295
456
1,255
456
1,220
465
1,180
468
T5 COOLING
SPEED
CFM
WATTS
1,440
426
1,390
428
1,365
440
1,335
440
1,295
456
1,255
456
1,220
465
1,180
468
T5 COOLING
SPEED
CFM
WATTS
1,440
426
1,390
428
1,365
440
1,335
440
1,295
456
1,255
456
1,220
465
1,180
468
T5 COOLING
SPEED
CFM
WATTS
1,637
444
1,593
454
1,541
459
1,497
473
1,450
478
1,407
485
1,357
493
1,304
502
T5 COOLING
CFM
WATTS
1,637
444
1,593
454
1,541
459
1,497
473
1,450
478
1,407
485
1,357
493
1,304
502
44

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gpgm3Apgm5Gpgm5

Table of Contents