Galaxy 3 Series Programming Manual

Section 4: Menu Options 11-19

Option 11 – Omit Zones (Quick Menu Option 0)
Code + ent + 11 + ent + A or B to select zone + # +
A or B to select zone + # + ..........
ent (to set) or esc (to select another option)
This option allows zones to be temporarily removed (omitted) from the system. Once a zone has been omitted
it does not generate an alarm condition (including tamper). The omitted zones are reinstated automatically
when the system is unset or manually when the zone omit option is disabled.
On selecting the Omit Zones option, the first zone that has the omit attribute enabled is displayed (refer to
option 52 = PROGRAM ZONE). If there are no omittable zones, then the message NO ENTRIES is
displayed.
Press the A or B keys to view other omittable zones. Press the # key to toggle the omit status of the required
zone. The display indicates the new omit status.
NOTE: A zone is omitted from the system as soon as it is selected.
This process is continued until all the required zones have been omitted:
pressing the ent key starts the timed setting routine. The number of zones omitted from the system are
displayed during the exit time countdown;
pressing the esc key returns to the 11 = OMIT ZONES without starting the setting routine.
On returning to the banner (normal or engineer) the keypad displays the message ZONES OMITTED.
Omitted zones remain omitted for one set period only or until they are manually reinstated to the system.
Outputs programmed as Zone Omit (mode programmed as reflex) are activated as soon as the zone is
omitted and remains active until the zone is reinstated.
11 - Omit Zones
13