Unsetting the System

Unsetting the System Using a PIN

During the unsetting procedure, initiated by the opening of FINAL or ENTRY zone on a set group, the
system is unset by entering the user code followed by the A key.
If the user does not have group choice, all of the groups assigned to the code are instantly unset.
If the user has group choice only the group that the FINAL or ENTRY zone is assigned to is
unset; all of the other groups remain set. The system displays the set status of the remaining
groups and prompts for the required groups to be unset. To unset the required groups press the
relevant number keys — the S or P (Set or Part Set) changes to flashing U — and then press the
ent key.
When the system/group is unset three short beeps are emitted to advise the user that the system/group is
unset

Engineer Unsetting

The engineer can only unset a system that was set using the engineer code. The engineer code cannot be used
to unset a system that was set by a user code.

Keyswitch Setting Options

Zones programmed as KEYSWITCH can be used to full set, part set and unset the system. Refer to option
52 = PROGRAM ZONE.

Setting the System with a Keyswitch

The KEYSWITCH starts the setting procedure of each of the groups assigned to the keyswitch zone. At the
end of the exit time, or when the setting procedure is terminated by a FINAL or PUSH-SET zone closing, the
ENTRY/EXIT HORN outputs and keypad buzzers become silent for four seconds, then emit two long tones
to confirm that the system is set.
NOTE: If the KEYSWITCH has its Part attribute enabled (refer to option 52 = PROGRAM ZONE) then
the KEYSWITCH part sets the system.

Unsetting the System with a Keyswitch

Activating the KEYSWITCH when the group that it is assigned to is set instantly unsets the group. All other
groups which have been "starred" to the KEYSWITCH are not affected and remain set.

Setting the System with Cards/Tags/Fobs

The Proximity user cards can be used to set and unset the system. This is done by assigning a MAX user
card (or fob) with one of the setting options (refer to option 42.1.8 = CODES.User Codes.MAX Func-
tion). When the card is held against a MAX module or keyprox for five seconds, the card held function
programmed to the card user is activated.
If the card user has a keypad assigned, the function will be shown as the assigned keypad. If the card user has
no keypad assigned then all keypads in the group assigned to the card user will show "Press any Key". If a
key is pressed the keypad containing the key to be pressed will show the card held function. If no keys are
pressed all keypads in the group(s) allocated to the card will show card the held menu function.