Cleveland 24-CEM-24 Specifications page 2

Two compartment, pressureless electric steam generator 24, 36 or 48 kw, 24” wide cabinet base design classic series

Advertisement

NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL, NSF and CSA.
Each compartment has capacity for:
Three, 12˝ x 20˝ x 2
Cafeteria Pans.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours of
use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS
TOTAL ALKALINITY
SILICA
pH FACTOR
CHLORINE
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals. The
use of highly mineralized water will mean that more
frequent servicing of the steam generator will be necessary.
The fact that a water supply is potable is not proof that it
will be suitable for the generator.
ELECTRIC
KW Volts
Watts Ph Amps Wire
24
208
21,500
1
103.4
2
220
24,000
1
109.1
2
240
24,000
1
100.0
2
440
20,200
1
45.9
2
480
24,000
1
50.0
2
208
21,500
3
59.7
3
220
24,000
3
63.1
3
240
24,000
3
57.8
3
440
20,200
3
26.5
3
480
24,000
3
28.9
3
600
24,000
3
23.1
3
360
21,500
3
34.5
4
380
24,000
3
36.5
4
415
24,000
3
33.4
4
WATER
DRAINAGE
C
1/4˝ NPT
The Floor Drain must be located
Cold Water Inlet
outside the confines of the
equipment base.
35 psi minimum
1 1/2˝ I.P.S. common drain.
60 psi maximum
Do not connect other units to this drain.
Do not use PVC pipe for drain.
1
˝ or six, 12˝ x 20˝ x 1˝ deep
2
less than 60 parts per million
less than 20 parts per million
less than 13 parts per million
greater than 7.5
less than 30 parts per million
KW Volts Watts Ph Amps Wire
36
208
32,200
3
89.5
220
36,000
3
94.6
240
36,000
3
86.7
440
30,200
3
39.7
480
36,000
3
43.4
600
36,000
3
34.7
360
32,200
3
51.7
380
36,000
3
54.8
415
36,000
3
50.1
48
208
42,900
3
119.2
220
48,000
3
126.1
240
48,000
3
115.6
440
40,300
3
52.9
480
48,000
3
57.8
600
48,000
3
46.2
360
42,900
3
68.9
380
48,000
3
73.0
415
48,000
3
66.9
CLEARANCE
D
Right - 3", Left - 3", Rear - 3"
(12" on control side if adjoin-
ing wall or equipment is over
30" high for service acess)
Contact factory for
variances to clearances.
(NOT TO SCALE)
III
SECT.
Litho in U.S.A.
3
3
3
3
3
3
4
4
4
3
3
3
3
3
3
4
4
4
2
PAGE
0707