Specifications For The Mac Controllers - Banner A-GAGE MINI-ARRAY MAC-1 Instruction Manual

Measuring light screen system
Hide thumbs Also See for A-GAGE MINI-ARRAY MAC-1:
Table of Contents

Advertisement

®
®
A-GAGE
MINI-ARRAY
Measuring Light Screen System
Emitter/Receiver Models
BMEL30..A / BMRL30.A
BMEL36..A / BMRL36.A
BMEL42..A / BMRL42.A
BMEL48..A / BMRL48.A
BMEL60..A / BMRL60..A
BMEL72..A / BMRL72..A
Beam Spacing
9.5 mm (3/8 in)
19.1 mm (3/4 in)

3.3 Specifications for the MAC Controllers

Supply Voltage and Current
16 to 30 V dc at 1.25 amps maximum (see current requirements for sensors)
Controller alone (without sensors connected) requires 0.1 amp
Inputs
MINI-ARRAY sensor input (5 connections); emitter and receiver wire in parallel
to five terminals
GATE input: Optically-isolated, requires 10 to 30 V dc (7.5K input impedance)
for gate signal
Discrete Outputs (MAC-1)
Output 1 (OUT 1): Reed relay contact rated 125 V ac/dc max., 10 VA max.
resistive load (non-inductive)
Output 2 (ALARM): Open collector NPN transistor rated 30 V dc max., 150 mA
max, short-circuit protected (may be configured as a second data analysis
output, system alarm output, or scan trigger output for a parallel array)
OFF-STATE Leakage Current: < 10 μA at 30 V dc
ON-STATE Saturation Voltage: <1 Volt at 10 mA, <1.5 Volt at 150 mA
Discrete Outputs (MACN-1)
Two open collector NPN transistor outputs
Discrete Outputs (MACP-1)
Two open collector PNP transistor outputs
Transistor rated 30 V dc max., 150 mA max, short circuit protected (may be
configured as a second data analysis output, system alarm output, or scan
trigger output for a parallel array)
OFF-STATE Leakage Current: <10 μA at 30 V dc
ON-STATE Saturation Voltage: <1 Volt at10 mA, <1.5 Volt at
150 mA
Discrete Outputs (MACV-1/MACI-1)
Alarm: Open collector NPN transistor rated 30 V dc max. 150 mA max, short
circuit protected
(may be configured as a data analysis output, system alarm output, or scan
trigger output for a parallel array)
OFF-STATE Leakage Current: <10 μA at 30 V dc
ON-STATE Saturation Voltage: <1 Volt at 10 mA, <1.5 Volt at150 mA
Discrete Outputs (MAC16P-1)
Sixteen open collector PNP transistor outputs
Discrete Outputs (MAC16N-1)
Sixteen open collector NPN transistor outputs
30 V dc max,150 mA max., short circuit protected
OFF-STATE leakage current: <10 μA
ON-STATE Saturation Voltage: <1 Volt at 10 mA; <1.9 V at 150 mA
8
Housing Length
L1
810 mm (31.9 in)
963 mm (37.9 in)
1115 mm (43.9 in)
1267 mm (49.9 in)
1572 mm (61.9 in)
1877 mm (73.9 in)
System Response Time
Outputs are not active for 5 seconds after system power up. Maximum
response time for the discrete outputs is two scan cycles. A scan cycle includes
a sensor scan plus any serial data transmission.
Serial transmission (if activated) follows every sensor scan.
Controller Programming
Via RS-232 to PC-compatible computer running Windows
and using Banner-supplied software
Analog Outputs
MACV-1: Two 0-10 Volts sourcing adjustable Null and Span (20 mA current
limit)
MACI-1: Two 4-20 mA current sinking adjustable Null and Span (16 to 30 V
input)
Resolution: Span minus Null, divided by the number of sensor channels
Linearity: 0.1% of Full Scale
Temp. Var.: 0.01% of Full Scale/°C
Serial Data Outputs
All Models: RS-232, ASCII or binary data format
Baud rate: 9600, 19.2K, or 38.4K 8 data bits, 1 start bit, 1 stop bit, even parity
Clear data may be suppressed; header string may be suppressed in binary
format
MAC-1, MACN-1, and MACP-1: Up to 15 Controllers may be given unique
address for RS-485 party line
Status Indicators
The following status LEDs are located on the front panel:
Plus three diagnostic LEDs:
www.bannerengineering.com - Tel: 763.544.3164
Distance Between Bracket Holes
L2
843.5 mm (33.23 in)
997.4 mm (39.29 in)
1148 mm (45.2 in)
1301 mm (51.2 in)
1606 mm (63.2 in)
1910 mm (75.2 in)
X (Distance for First Optical Channel)
38.1 mm (1.5 in)
42.9 mm (1.69 in)
OUTPUT 1 (red) (name and function vary depending on model): Indicates
active output
ALARM (red): Indicates that Output 2 or 16 is active (depending on model)
GATE (red): Indicates voltage is applied to GATE input
ALIGN (green): Indicates sensor aligned (excess gain >1x)
DIAG1 (green): Indicates power is applied to the module
DIAG2 (red): Indicates receiver failure
DIAG3 (red): Indicates emitter failure
L3
786.6 mm (30.97 in)
940.5 mm (37 in)
1091 mm (43 in)
1244 mm (49 in)
1549 mm (61 in)
1853 mm (73 in)
®
operating system