Specifications; Specifications For The Emitter/Receiver Pairs; Dimensions For The Emitters And Receivers - Banner A-GAGE MINI-ARRAY MAC-1 Instruction Manual

Measuring light screen system
Hide thumbs Also See for A-GAGE MINI-ARRAY MAC-1:
Table of Contents

Advertisement

3 Specifications

3.1 Specifications for the Emitter/Receiver Pairs

Range (9.5 mm Beam Spacing)
0.6 m to 6.1 m (2 ft to 20 ft) for sensors < 4 ft
0.6 m to 4.6 m (2 ft to 15 ft) for sensors > 4 ft
Maximum range is specified at the point where 3× excess gain remains.
Minimum Object Sensitivity (9.5 mm Beam Spacing)
19.1 mm (0.75 in)
Interlaced Mode: 12.7 mm (0.5 in)
Assumes sensing is in middle one-third of scanning range.
Supply Voltage and Current (Emitter)
0.10 amps at 12 V dc
Maximum current is for a 6 ft sensor.
Status Indicators (Emitter)
Red LED lights for proper operation
Construction
Aluminum housing with black anodized finish; acrylic lens cover
Sensor Scan Time
55 microseconds per beam, plus 1 millisecond processing time per scan
Assumes straight scan, continuous scan, and TBB mode
Environmental Rating
NEMA 4, 13 (IEC IP65)
Operating Conditions
−20 °C to +70 °C (−4 °F to +158 °F)
95% maximum relative humidity (non-condensing)

3.2 Dimensions for the Emitters and Receivers

With Mounting Bracket Flanges Out
L1
X
18.3 mm
[0.72"]
Emitter/Receiver Models
BMEL6..A / BMRL6..A
BMEL12..A / BMRL12..A
BMEL18..A / BMRL18..A
BMEL24..A / BMRL24..A
L2
2.5 mm
[0.10"]
Housing Length
L1
201 mm (7.9 in)
356 mm (14 in)
505 mm (19.9 in)
659 mm (26 in)
www.bannerengineering.com - Tel: 763.544.3164
®
A-GAGE
MINI-ARRAY
Range (19.1 mm Beam Spacing)
0.9 m to 17 m (3 ft to 55 ft) for sensors < 4 ft
0.9 m to 14 m (3 ft to 45 ft)for sensors > 4 ft
Maximum range is specified at the point where 3× excess gain remains.
Minimum Object Sensitivity (19.1 mm Beam Spacing)
38.1 mm (1.5 in)
Interlaced Mode: 25.4 mm (1 in)
Assumes sensing is in middle one-third of scanning range.
Supply Voltage and Current (Receiver)
9.5 mm beams: 0.75 amps at 12 V dc maximum
19.1 mm beams: 0.50 amps at 12 V dc maximum
Maximum current is for a 6 ft sensor.
Status Indicators (Receiver)
Green: sensors aligned (> 3× excess gain)
Amber: marginal alignment (1×-3× excess gain)
Red: sensors misaligned or beam(s) blocked
Connections
Emitter and receiver connect to controller using two 5-conductor quick-
disconnect cables (one each for emitter and receiver), ordered separately.
Cables measure 8.1 mm (0.32 in ) dia., and are shielded and PVC-jacketed;
conductors are 20-gauge.
Use only Banner cables, which incorporate a ""twisted pair" for noise immunity
on RS-485 data communication lines.
Emitter and receiver cables may not exceed 250 ft each.
With Mounting Bracket Flanges In
38.1 mm square
[1.5"]
L3
Distance Between Bracket Holes
L2
233.9 mm (9.21 in)
389.7 mm (15.35 in)
538.7 mm (21.22 in)
693.2 mm (27.31 in)
®
Measuring Light Screen System
10.2 mm
[0.4"]
L3
177 mm (6.97 in)
332.8 mm (13.1 in)
481.8 mm (18.97 in)
636.3 mm (25.05 in)
7