Features; Mini-Array Models - Banner A-GAGE MINI-ARRAY MAC-1 Instruction Manual

Measuring light screen system
Hide thumbs Also See for A-GAGE MINI-ARRAY MAC-1:
Table of Contents

Advertisement

1 Features

WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death.
This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety
applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output
condition.

1.1 MINI-ARRAY Models

Each A-GAGE MINI-ARRAY system must include one controller and an emitter/receiver pair of matching length and resolution. Configure
and monitor the system using the supplied software and a user-supplied PC-compatible computer.
These MAC series controllers operate on 16 to 30 V dc and have one sensor pair input and one
gate input.
MAC Series Controllers
Models
Output 1
MAC-1
Discrete Reed Relay
MACN-1
Discrete NPN
MACP-1
Discrete PNP
Two Analog (0 to
MACV-1
10V dc Sourcing)
Two Analog (4 to 20
MACI-1
mA Sinking)
MAC16N-1
16 Discrete NPN Outputs
MAC16P-1
16 Discrete PNP Outputs
The dimensions for the MAC series controllers listed are: 110 × 100 × 75 mm (4.3 in × 3.9 in × 3
in).
Measuring Light Screen system for inspection and profiling applications
Modular system with compact controller and a variety of BMEL/BMRL series MINI-
ARRAY emitters and receivers
Sensors available with either 9.5 mm (3/8 in) or 19.1 mm (3/4 in) beam spacing and with
array lengths from 6 in to 4 ft (in 6 in increments), plus 5 ft and 6 ft models
Controller is programmable for any one or two of ten measurement modes (depending
on model) and any one of four scanning modes, using a computer running Windows
Vista, or 7, and the Banner-supplied software
Software is also supplied for display of error analysis (via controller self-diagnostics) and
for sensor alignment
System status, including alignment, is displayed via LED indicators on the controller and
on the receivers
Controller may be programmed for blanking to ignore activity in one or two fields along
the length of the array
Programmable hysteresis at the high and/or low limit of each measurement area
provides smoothing of output response; also programmable for number of consecutive
scans before an output update
Separate gate input (e.g., from a presence sensor) allows control of scan initiation
Supports serial communication with a computer or PLC via RS-232C interface; enables a
computer or PLC to process scan data and/or initiate scans; serial data may be either
ASCII or binary
Serial
Scan Analysis
Output 2
Output
Discrete NPN
RS-232 and
RS-485
Discrete PNP
Discrete NPN
RS-232
www.bannerengineering.com - Tel: 763.544.3164
®
A-GAGE
MINI-ARRAY
PSF Parameter
Modes
Part Number
8
43989
10
59114
®
Measuring Light Screen System
®
XP,
3

Advertisement

Table of Contents
loading

Table of Contents