Exhaust Restrictor Instructions
Exhaust restrictors are recommended for these verti-
cally terminated products which have excessive draft.
Exhaust restrictors will compensate for high draft, and
restore visual flame height. If the vent configuration has
a total vertical of 15-60 feet, an exhaust restrictor may
be needed. The exhaust restrictor can be located in the
appliance manual bag.
Exhaust Restrictor Installation
1. JADE42IN/JADE42IL Only:
shield by removing two wing nuts from top front of heat
shield and two screws that secure the heat shield to
back wall of fireplace. Retain heat shield and fasten-
ers.
2. JADE32IN/JADE42IN/JADE42IL: Center the ex-
haust restrictor in the open end of the exhaust outlet
and secure through the slots on the exhaust restrictor
with the two 1/4 in. self-tapping screws provided in
the appliance manual bag. See Figure 4.15.
3. JADE42IN/JADE42IL Only: Reinstall shield by secur-
ing it with the two wing nuts and two screws previously
removed in Step 1.
Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18
Remove inner heat
SCREWS
HEAT SHIELD
EXHAUST RESTRICTOR
INSTALLED SCREWS
Figure 4.15 Installing Restrictor
WING NUTS