Majestic JADE32IN Installation Manual page 14

Hide thumbs Also See for JADE32IN:
Table of Contents

Advertisement

Framing
This appliance is designed to be recessed into combus-
tible framing with non-combustible material pre-installed
on top and side. Drywall or combustible materials (mini-
mum 1/2 inch thick) are designed to contact the non-
combustible material/appliance as called out in Section
10 Finishing.
This appliance has been thoroughly tested to minimize
drywall cracking and/or the protrusion of screws "screw
pops" when framed as shown below.
Framing should be done in a manner similar to framing a
window or door: Double-2x4/2x6 as a header for horizon-
tal strength and utilizing Jack or Trimmer stud fastened to
the King studs for vertical strength.
If elevating the appliance, the base of the unit should also
be constructed in a similar manner to prevent settling.
Note: Header MUST be installed on end
as shown in the diagram.
HEADER: TWO 2 X 4'S OR 2 X 6'S
INSTALLED ON END
B
D
JACK (TRIMMER) STUD
Models
in.
JADE32IN
mm
in.
JADE42IN
JADE42IL
mm
* Adjust framing dimensions for interior sheathing (such as sheetrock)
Figure 3.6 Clearances to Combustibles
14
Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18
A
C
KING STUD
A
B
C
Rough
Rough
Rough
Opening
Opening
Opening
(Vent Pipe)
(Height)
(Depth)
8-5/8
36-1/2
17-3/4
219
927
451
8-5/8
32-3/4
17-3/4
219
832
451
Note: Refer to Section 10 for important information
related to facing, drywall specifications and decorative
front information.
MINIMUM FRAMING DIMENSIONS*
D
E
Rough
Clearance
Combustible
Opening
to Ceiling
Floor
(Width)
37
31
940
787
49
31
1245
787
MEASURE FROM TOP
OF APPLIANCE OPENING
G
J
I
F
G
H
Combustible
Behind
Flooring
Appliance
0
0
1/2
0
0
13
0
0
1/2
0
0
13
E
H
I
J
Sides of
Front of
Appliance
Appliance
1/2
36
13
914
1/2
36
13
914