Top Vent - Horizontal Termination - (continued)
Three Elbows
WARNING
Risk of Fire!
This vent configuration can ONLY be used for
JADE42IN Natural Gas appliances.
V Minimum
4 ft.
1.2 m
H
+ H
+ H
1
2
3
V
MAX. = 7 ft (2.1 m)
1
V
1
Figure 4.13
Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K • 10/18
H
+ H
+ H
MAXIMUM
1
2
3
JADE42IN (NG ONLY)
15 ft.
4.6 m
MAX. = 15 ft. (4.6 m)
INSTALLED
HORIZONTALLY
H
1
Note: Use SLP Series
components only.
Note: There MUST be a 25% reduction
in total H when using SLP-FLEX Series
(6-5/8 inch) vent except when using
the simple up and out installation. See
Figure 4.8.
CAUTION: The SLP-HRC-SS termination caps are
not approved for use with these models. May lead to
elevated glass temperature that may cause tempered
glass breakage.
H
2
H
3
INSTALLED
HORIZONTALLY
25