Table 11: Driver Parameters (Continued)
ResetFF = n
ResetTPRLO = n
RetryInterval = n
RetryloTimeOut = n
RTTOV = n
ScanDown = n
SilFlags = n
SimulateDevice = n
SnsALL = n
Topology = n
TrafficCop = n
Host Bus Adapter for Windows and Linux Installation Guide
Values 0 or 1. Default = 1. 0 = ResetBus translates to LIP (F7).
1 = ResetBus translates to LIP (FF). Used for WolfPack to force
reservations to be freed when ResetBus issued. Only
meaningful for FC_AL topology and Seagate native FC hard
drives.
Values 0 or 1. Default = 1. 0 = ResetBus translates to LIP (). 1
= ResetBus translates to ThirdPartyProcessLogout + LIP ().
Used for WolfPack to force reservations to be freed when
ResetBus is issued.
Values are in seconds from 2-255. Default = 45. Used for
time-out interval if RetryloTimeOut = 1. Must be shorter than
Class driver TimeOutInterval.
Vaules 0 or 1. Default = 1. 1 = lets an HBA to time-out I/O
prior to port driver's time-out which causes a LIP/Link Reset.
Values are in milliseconds from 100 to 511. Default = 256.
Represents time-out between phases of Off-line to On-line
protocol.
Values 0 or 1. Default = 0. 0 = Lowest AL_PA = Lowest
physical disk (ascending AL_PA order). 1 = Highest AL_PA =
Lowest Physical Disk (ascending SEL_ID order).
Values from 0-2. Default = 0. Controls which driver interface
to use. 0 = automode; attempt SLI-2 first. If that fails, uses
SLI-1. 1 = always use SLI-1. 2 = always use SLI-2.
Values 0 or 1. Default = 0. 0 = do not create a "dummy" disk
device. 1 = create a dummy disk to force the driver to load
even if no disk devices are present at boot time.
Values 0 or 1. Default = 1. Controls which N_Ports are
queried from the NameServer. 0 = SCSI FCP only. 1 = All
N_Ports.
Values 0 or 1. Default = 0. 0 = FC_AL (loop), 1 = PT-PT
Fabric. When set to 1, FLOGI, SCR/RSCN and NameServer
queries are employed.
Values 0 or 1. Default = 0. 1 = enable FC-AL loop master to
run unfair and break potential arbitration problems by
sending frames to itself. 0 = run fair all the time.
Diagnostic and Configuration Utilities