HP StorageWorks A7298A Installation Manual page 53

Host bus adapter for windows and linux
Hide thumbs Also See for StorageWorks A7298A:
Table of Contents

Advertisement

Table 5: SCSI Port Error Log Codes (Continued)
0x10
Offset
0xE2
0xE3
0xE4
0xE5
0xE6
0xE7
0xE8
0xE9
0xEB
0xEC
0xED
0xEF
0xF0
0xF1
0xF2
0xF3
0xF4
0xF5
Host Bus Adapter for Windows and Linux Installation Guide
Explanation
Mailbox cmd time-out
Mailbox rsp err
HBA not ready after init
Requested loop but link = PT-PT
Mailbox int. but cmd not
complete
SRB already queued to ring
RESTART failed
PORT BYPASS (LPB) received
Unknown IOCB cmd rsp
Uncached extension alloc. Error
Link down @ boot time (30 sec)
Too many interrupts at initial
boot
Rcv ELS request (possible logout)
(Windows NT)
LinkUp error; LP8 down, driver
up
LinkUp w/ illegal or corrupt RPI
DeQueue ring->iotcmd.head
HBA reset
PCP_IXXX_CR IOCB rsp err
0x11 to 0x13 Further
Information
0x11 = command
0x11 = command, 12-13 =
mbxstatus
Status register bytes 1-3 in event
11-13
0x11 = MB cmd, 12-13 = mbxstatus
0x11 = 15:8 = cmd field
0x11 = ELS type, 12-13 = X_ID
0x11 = parameter field, 12 = IOCB
cmd
0x11 = parameter field, 12 = IOCB
cmd
0x11 = caller ID
0x11 = coded reason for reset:
Bit 0 = IOCB requeue; bit 1 = readla
retry
Bit 2 = initlink retry; bit 3 = rstbus
retry
Bit 4 = mailbox time-out
0x11 = cmdstat, 12 = parm err, 13 =
ALPA
Troubleshooting
53

Advertisement

Table of Contents