Instruction Set
Indirect Addressing
Designating Constants
3-7-4

Coding Right-hand Instructions

72
Abbreviation
ER
Instruction Execution Error Flag
CY
Carry Flag
LE
Less Than Flag
EQ
Equals Flag
GR
Greater Than Flag
ER is the flag most commonly used for monitoring an instruction's execution.
When ER goes ON, it indicates that an error has occurred in attempting to
execute the current instruction. The Flags subsection of each instruction lists
possible reasons for ER being ON. ER will turn ON if operands are not en-
tered correctly. Instructions are not executed when ER is ON. A table of in-
structions and the flags they affect is provided in Appendix E Error and Arith-
metic Flag Operation.
When the DR area is specified for an operand, an indirect address can be
used. Indirect DR addressing is specified by placing an asterisk before the
DR: *DR.
When an indirect DR address is specified, the designated DR word will con-
tain the address of the DR word that contains the data that will be used as
the operand of the instruction. If, for example, *DR 01 was designated as the
first operand and LR 00 as the second operand of MOV(30), the contents of
DR 01 was 0006, and DR 06 contained 5555, the value 5555 would be
moved to LR 00.
MOV(30)
*DR 01
LR 00
When using indirect addressing, the address of the desired word must be in
BCD and it must specify a word within the DR area. In the above example,
the content of *DR 00 would have to be in BCD and between 0000 and
1515.
Although data area addresses are most often given as operands, many oper-
ands and all definers are input as constants. The available value range for a
given definer or operand depends on the particular instruction that uses it.
Constants must also be entered in the form required by the instruction, i.e., in
BCD or in hexadecimal.
Writing mnemonic code for ladder instructions has already been described
for ladder instructions. Converting the information in the ladder diagram sym-
bol for all other instructions follows the same pattern, as described below,
and is not specified for each instruction individually.
The first word of any instruction defines the instruction and provides any de-
finers. If the instruction requires only a signal bit operand with no definer, the
Name
Word
Content
DR 00
DR 01
Indirect
DR 02
address
DR 06
DR 07
DR 08
Section 3-7
Bit
0311
0312
0313
0314
0315
4C23
0006
Indicates
F3A3
DR 06.
5555
2255
5555
moved to
D1C5
LR 00.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac mini sp16Sysmac mini sp20

Table of Contents