Programming Q parameters | String parameters
Reading out machine parameters
With the CFGREAD function, you can read out machine parameters
of the control as numerical values or as strings. The read-out values
are always output in metric units of measure.
In order to read out a machine parameter, you must use the control's
configuration editor to determine the parameter name, parameter
object, and, if they have been assigned, the group name and index:
Icon
Type
Key
Entity
Attribute
Index
If you are in the configuration editor for the user
parameters, you can change the display of the existing
parameters. In the default setting, the parameters are
displayed with short, explanatory texts.
Further information: User's Manual for Setup, Testing
and Running NC Programs
Each time you want to interrogate a machine parameter with the
CFGREAD function, you must first define a QS parameter with
attribute, entity and key.
The following parameters are read in the CFGREAD function's dialog:
KEY_QS: Group name (key) of the machine parameter
TAG_QS: Object name (entity) of the machine parameter
ATR_QS: Name (attribute) of the machine parameter
IDX: Index of the machine parameter
HEIDENHAIN | TNC 620 | Klartext Programming User's Manual | 01/2022
Meaning
Group name of the machine parameter
(if available)
Parameter object (name begins with
Cfg...)
Name of the machine parameter
List index of a machine parameter (if
available)
Example
CH_NC
CfgGeoCycle
displaySpindleErr
[0]
9