Operating Instructions
Proline Promass E 100
EtherNet/IP
Coriolis Mass Flow Measuring System
BA01064D/06/EN/01.12
71165109
Valid as of version
01.00.zz (Device firmware)

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser Proline Promass E 100

  • Page 1 Operating Instructions Proline Promass E 100 EtherNet/IP Coriolis Mass Flow Measuring System BA01064D/06/EN/01.12 71165109 Valid as of version 01.00.zz (Device firmware)
  • Page 2 • The manufacturer reserves the right to modify technical data in line with technological developments without prior notice. Your Endress+Hauser sales center will supply you with current information and updates to this manual.
  • Page 3: Table Of Contents

    Proline Promass E 100 EtherNet/IP Table of contents Table of contents Document information ....5 Electrical connection ....23 Document function .
  • Page 4 10.4.3 Carrying out a sensor adjustment ..48 14.3 Endress+Hauser services ....72 10.4.4 Configuring the totalizer ... . . 49 10.5 Simulation .
  • Page 5: Document Information

    Proline Promass E 100 EtherNet/IP Document information Document information Document function These Operating Instructions contain all the information that is required in various phases of the life cycle of the device: from product identification, incoming acceptance and storage, to mounting, connection, operation and commissioning through to troubleshooting, maintenance and disposal.
  • Page 6: Symbols For Certain Types Of Information

    The following document types are available: • On the CD-ROM supplied with the device • In the Download Area of the Endress+Hauser Internet site: www.endress.com ® Download For a detailed list of the individual documents along with the documentation code (®...
  • Page 7: Standard Documentation

    Proline Promass E 100 EtherNet/IP Document information 1.3.1 Standard documentation Document type Purpose and content of the document Technical Information Planning aid for your device The document contains all the technical data on the device and provides an overview of the accessories and other products that can be ordered for the device.
  • Page 8: Basic Safety Instructions

    Observe the specified maximum process pressure. ► Verification for borderline cases: For special fluids and fluids for cleaning, Endress+Hauser is glad to provide assistance in verifying ► the corrosion resistance of fluid-wetted materials, but does not accept any warranty or liability as minute changes in the temperature, concentration or level of contamination in the process can alter the corrosion resistance properties.
  • Page 9: Workplace Safety

    It meets general safety standards and legal requirements. It also complies with the EC directives listed in the device-specific EC Declaration of Conformity. Endress+Hauser confirms this by affixing the CE mark to the device. Endress+Hauser...
  • Page 10: Product Description

    Registered trademark of the Microsoft Corporation, Redmond, Washington, USA Ò TRI-CLAMP Registered trademark of Ladish & Co., Inc., Kenosha, USA Ò Ò Ò Applicator , FieldCare , Field Xpert , HistoROM Registered or registration-pending trademarks of the Endress+Hauser Group Endress+Hauser...
  • Page 11: Incoming Acceptance And Product

    A0015502 A0013699 Do the nameplate data match the ordering information on the delivery note? A0015502 A0013697 Is the CD-ROM with the Technical Documentation and documents present? If one of the conditions is not satisfied, contact your Endress+Hauser Sales Center. Endress+Hauser...
  • Page 12: Product Identification

    Incoming acceptance and product identification Proline Promass E 100 EtherNet/IP Product identification The following options are available for identification of the measuring device: • Nameplate specifications • Order code with breakdown of the device features on the delivery note • Enter serial numbers from nameplates in W@M Device Viewer (www.endress.com/deviceviewer): All information about the measuring device is displayed.
  • Page 13: Sensor Nameplate

    Proline Promass E 100 EtherNet/IP Incoming acceptance and product identification 4.2.2 Sensor nameplate 3 4 5 6 Order code: Ser. no.: Ext. ord. cd.: Size: Ptest = Material: 0044 Patents Date: 322541-0000 13 14 A0013907 å 3 Example of a sensor nameplate...
  • Page 14: Symbols On Measuring Device

    Incoming acceptance and product identification Proline Promass E 100 EtherNet/IP 4.2.3 Symbols on measuring device Symbol Meaning WARNING! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury. Reference to documentation Refers to the corresponding device documentation.
  • Page 15: Storage And Transport

    Proline Promass E 100 EtherNet/IP Storage and transport Storage and transport Storage conditions Observe the following notes for storage: • Store in the original packaging to ensure protection from shock. • Do not remove protective covers or protective caps installed on process connections. They prevent mechanical damage to the sealing surfaces and fouling in the measuring tube.
  • Page 16: Packaging Disposal

    Storage and transport Proline Promass E 100 EtherNet/IP Packaging disposal All packaging materials are environmentally friendly and 100% recyclable: • Measuring device secondary packaging: polymer stretch film that conforms to EC Directive 2002/95/EC (RoHS). • Packaging: – Wood crate, treated in accordance with ISPM 15 standard, which is confirmed by the affixed IPPC logo.
  • Page 17: Mounting

    Proline Promass E 100 EtherNet/IP Mounting Mounting Mounting requirements No special measures such as supports are necessary. External forces are absorbed by the construction of the device. 6.1.1 Mounting position Mounting location A0015595 To prevent measuring errors arising from accumulation of gas bubbles in the measuring tube, avoid the following mounting locations in the pipe: •...
  • Page 18 Mounting Proline Promass E 100 EtherNet/IP A0015596 å 4 Installation in a down pipe (e.g. for batching applications) Supply tank Sensor Orifice plate, pipe restriction Valve Batching tank Æ Orifice plate, pipe restriction [mm] [in] [mm] [in] 0.24 ½ 0.40 0.55...
  • Page 19: Requirements From Environment And Process

    Proline Promass E 100 EtherNet/IP Mounting If a sensor is installed horizontally with a curved measuring tube, match the position of the sensor to the fluid properties. A0014057 å 5 Orientation of sensor with curved measuring tube Avoid this orientation for fluids with entrained solids: Risk of solids accumulating.
  • Page 20: Special Mounting Instructions

    Mounting Proline Promass E 100 EtherNet/IP A0015594 Heating NOTICE Electronics can overheat due to elevated ambient temperature! Observe maximum permitted ambient temperature for the transmitter (® ä 19). ► Depending on the fluid temperature, take the device orientation requirements into account ►...
  • Page 21: Mounting The Measuring Device

    Proline Promass E 100 EtherNet/IP Mounting Rupture disk Make sure that the function and operation of the rupture disk is not impeded through the installation of the device. The position of the rupture disk is indicated on a sticker applied over it. If the rupture disk is triggered, the sticker is destroyed.
  • Page 22: Post-Mounting Check

    Mounting Proline Promass E 100 EtherNet/IP 2. Install the measuring device or turn the transmitter housing so that the cable entries do not point upwards. Ã A0013964 Post-mounting check Is the device damaged (visual inspection)? Does the measuring device conform to the measuring point specifications? For example: •...
  • Page 23: Electrical Connection

    Proline Promass E 100 EtherNet/IP Electrical connection Electrical connection Connection conditions 7.1.1 Required tools • For cable entries: Use corresponding tools • For securing clamp (on aluminum housing): Allen screw3 mm • For securing screw (for stainless steel housing): open-ended wrench 8 mm •...
  • Page 24: Terminal Assignment

    Electrical connection Proline Promass E 100 EtherNet/IP 7.1.3 Terminal assignment Transmitter EtherNet/IP connection version A0017054 Order code for "Power supply", option D: DC 24 V Order code for "Output", option N: EtherNet/IP 7.1.4 Pin assignment, device plug Supply voltage for all communication types except Modbus RS485 intrinsically safe (on the device...
  • Page 25: Connecting The Measuring Device

    Proline Promass E 100 EtherNet/IP Electrical connection Connecting the measuring device NOTICE Limitation of electrical safety due to incorrect connection! Have electrical connection work carried out by correspondingly trained specialists only. ► Observe applicable federal/national installation codes and regulations. ►...
  • Page 26: Hardware Settings

    Electrical connection Proline Promass E 100 EtherNet/IP 8 mm 8 mm 3 mm 10 (0.4) mm (in) A0017844 å 7 Device versions with connection examples Cable Connector for signal transmission Connector for supply voltage For device version with connector: only pay attention to Step 6.
  • Page 27: Ensuring The Degree Of Protection

    Proline Promass E 100 EtherNet/IP Electrical connection Addressing data IP address and configuration options 1st octet 2nd octet 3rd octet 4th octet 192. 168. ¯ ¯ Can only be configured via software addressing Can be configured via software addressing and...
  • Page 28: Post-Connection Check

    Electrical connection Proline Promass E 100 EtherNet/IP 4. To ensure that moisture does not enter the cable entry, route the cable so that it loops down before the cable entry ("water trap"). Ã A0013960 5. Insert dummy plugs into unused cable entries.
  • Page 29: Operation Options

    Proline Promass E 100 EtherNet/IP Operation options Operation options Overview of operation options A0017760 Computer with Web browser (e.g. Internet Explorer) or with "FieldCare" operating tool Automation system, e.g. "RSLogix" (Rockwell Automation) and work station for measuring device operation with Add-on Profile Level 3 for "RSLogix 5000"...
  • Page 30: Structure And Function Of The Operating Menu

    Operation options Proline Promass E 100 EtherNet/IP Structure and function of the operating menu 8.2.1 Structure of the operating menu For an overview of the operating menu with menus and parameters (® ä 89) Operating menu for operators and maintenances Web server language Display/operat.
  • Page 31: Operating Philosophy

    Proline Promass E 100 EtherNet/IP Operation options 8.2.2 Operating philosophy The individual parts of the operating menu are assigned to certain user roles. Each user role corresponds to typical tasks within the device lifecycle. Menu User role and tasks Content/meaning Display/operat.
  • Page 32: Prerequisites

    Operation options Proline Promass E 100 EtherNet/IP 8.3.2 Prerequisites Hardware Connecting cable Standard Ethernet cable with RJ45 connector Computer RJ45 interface Measuring device Web server must be enabled; factory setting: ON For information on enabling the Web server (® ä 34)
  • Page 33: Logging On

    Proline Promass E 100 EtherNet/IP Operation options Device tag Webserv.language English Ent. access code Access stat.tool Maintenance A0017362 Device tag (® ä 47) Picture of device If a login page does not appear, or if the page is incomplete (® ä 58) 8.3.4...
  • Page 34: Disabling The Web Server

    Operation options Proline Promass E 100 EtherNet/IP Function row Functions Meaning Measured values The measured values of the device are displayed Menu Access to the operating menu structure of the device, same as for the operating tool Device status Displays the diagnostic messages currently pending, listed in order of priority •...
  • Page 35: Access To The Operating Menu Via The Operating Tool

    Proline Promass E 100 EtherNet/IP Operation options Access to the operating menu via the operating tool 8.4.1 Connecting the operating tool Via service interface (CDI-RJ45) A0016940 Service interface (CDI -RJ45) and EtherNet/IP interface of the measuring device with access to the integrated Web server Computer with Web browser (e.g.
  • Page 36: Fieldcare

    FieldCare Function scope FDT-based plant asset management tool from Endress+Hauser. It can configure all smart field devices in a system and helps you manage them. By using the status information, it is also a simple but effective way of checking their status and condition.
  • Page 37 Proline Promass E 100 EtherNet/IP Operation options User interface A0017402-EN Header Picture of device Device tag (® ä 54) Status area with status signal (® ä 60) Display area for current measured values (® ä 54) Event list with additional functions such as save/load, events list and document creation...
  • Page 38: System Integration

    System integration Proline Promass E 100 EtherNet/IP System integration Overview of device description files 9.1.1 Current version data for the device Firmware version 01.00.zz • On the title page of the Operating instructions • On transmitter nameplate • Parameter firmware version Diagnostics ®...
  • Page 39: Commissioning

    Proline Promass E 100 EtherNet/IP Commissioning Commissioning 10.1 Function check Before commissioning the device, make sure that the post-installation and post-connection checks have been performed. • "Post-mounting check" checklist (® ä 22) • "Post-connection check" checklist (® ä 28) 10.2 Configuring the device address via software Software addressing is carried out in the Communication submenu.
  • Page 40 Commissioning Proline Promass E 100 EtherNet/IP Structure of the submenu ® System units Mass flow unit Mass unit Volume flow unit Volume unit Corrected volume flow unit Corrected volume unit Density unit Reference density unit Temperature unit Pressure unit Parameter overview with brief description...
  • Page 41 Proline Promass E 100 EtherNet/IP Commissioning Corrected volume flow unit Select the unit for corrected Unit choose list Country-dependent: volume flow. • Nl/h • Scf/min Result The selected unit applies for: – Output – Low flow cut off – Simulation process...
  • Page 42: Selecting And Setting The Medium

    Commissioning Proline Promass E 100 EtherNet/IP 10.3.2 Selecting and setting the medium The Medium selection submenu contains parameters that have to be configured for selecting and setting the medium. Navigation path "Setup" menu ® Medium selection Structure of the submenu ®...
  • Page 43: Configuring Communication Interface

    Proline Promass E 100 EtherNet/IP Commissioning External pressure The following option is External value 0 to 99 999 [bar, psi] Country-dependent: selected in the • 1.01325 bar Pressure • 14.7 psi compensation parameter: External value 10.3.3 Configuring communication interface The Communication submenu guides you systematically through all parameters that must be configured for selecting and setting the communication interface.
  • Page 44 Commissioning Proline Promass E 100 EtherNet/IP Subnet mask Enter the subnet mask of the Max. 12-digit numerical 255.255.255.0 measuring device. values, e.g.: 255.255.255.248 Default gateway Enter the default gateway of Max. 12-digit numerical 192.168.1.212 the measuring device. values, e.g.: 192.93.179.254...
  • Page 45: Configuring The Low Flow Cut Off

    Proline Promass E 100 EtherNet/IP Commissioning 10.3.4 Configuring the low flow cut off The Low flow cut off submenu contains parameters that have to be set for configuring the low flow cut off. Navigation path "Setup" menu ® Low flow cut off...
  • Page 46: Configuring The Partial Filled Pipe Detection

    Commissioning Proline Promass E 100 EtherNet/IP 10.3.5 Configuring the partial filled pipe detection The Partially filled pipe detection submenu contains parameters that have to be set for configuring empty pipe detection. Navigation path "Setup" menu ® Partial filled pipe detection Structure of the submenu Partial filled pipe detection ®...
  • Page 47: Advanced Settings

    Proline Promass E 100 EtherNet/IP Commissioning 10.4 Advanced settings The Advanced setup menu with its submenus contains all parameters needed for specific settings. Navigation path "Setup" menu ® Advanced setup Overview of the parameters and submenus in the "Advanced setup" menu taking the example of the Web browser ®...
  • Page 48: Carrying Out A Sensor Adjustment

    Commissioning Proline Promass E 100 EtherNet/IP Corrected volume flow calculation External reference density Fixed reference density Reference temperature Linear expansion coefficient Square expansion coefficient Parameter overview with brief description Parameter Prerequisites Description Selection/input Factory settings Corrected volume – Select the reference density Calculated •...
  • Page 49: Configuring The Totalizer

    Proline Promass E 100 EtherNet/IP Commissioning Navigation path "Setup" menu ® Advanced setup ® Sensor adjustment Structure of the submenu Sensor adjustment ® Installation direction ® Zero point adjustment Zero point adjustment control Progress Parameter overview with brief description Parameters...
  • Page 50: Simulation

    Commissioning Proline Promass E 100 EtherNet/IP Assign process Select process • Off Mass flow variable variable for totalizer. • Mass flow • Volume flow Result • Corrected The selection volume flow determines the choose list of the Unit parameter. Unit...
  • Page 51: Protecting Settings From Unauthorized Access

    Proline Promass E 100 EtherNet/IP Commissioning Value process One of the following options is Enter the simulation Depends on the variable selected in the Assign value for the process variable simulation process variable selected process selected variable. parameter: • Mass flow •...
  • Page 52 Commissioning Proline Promass E 100 EtherNet/IP The parameter values are now read only and cannot be edited any more: • Via service interface (CDI-RJ45) • Via Ethernet network OFF ON - Write protection - Default Ethernet network settings IP 192.168.1.212 A0017915 1.
  • Page 53: Operation

    Proline Promass E 100 EtherNet/IP Operation Operation 11.1 Read out and modify current Ethernet settings If the Ethernet settings such as the IP address of the measuring device are unknown, they can be read out and modified as explained in the following example for an IP address.
  • Page 54: Reading Measured Values

    Operation Proline Promass E 100 EtherNet/IP Navigation path "Display/operation" menu ® Locking status Function scope of "Locking status" parameter Options Description Hardware locked The write protection switch (DIP switch) for hardware locking is activated on the I/O electronics module. This prevents write access to the parameters (® ä 51).
  • Page 55: Totalizer

    Proline Promass E 100 EtherNet/IP Operation Density – Displays the density Floating-point number currently measured with sign Reference density – Displays the density Floating-point number currently measured at with sign reference temperature Temperature – Displays the medium Floating-point number temperature currently...
  • Page 56: Adapting The Measuring Device To The Process Conditions

    Operation Proline Promass E 100 EtherNet/IP 11.4 Adapting the measuring device to the process conditions The following are available for this purpose: • Basic settings using the Setup menu (® ä 39) • Advanced settings using the Advanced setup menu (® ä 47) 11.5...
  • Page 57 Proline Promass E 100 EtherNet/IP Operation Control totalizer 1-3 One of the following options is Control totalizer • Totalize Totalize selected in the Assign process value. • Reset + hold • Preset + hold variable parameter of the • Reset + totalize Totalizer 1-3 submenu: •...
  • Page 58: Diagnostics And Troubleshooting

    Diagnostics and troubleshooting Proline Promass E 100 EtherNet/IP Diagnostics and troubleshooting 12.1 General troubleshooting For output signals Problem Possible cause Remedy Green power LED on the main Supply voltage does not match that Apply the correct supply voltage electronics module of the transmitter is specified on the nameplate.
  • Page 59: Diagnostic Information Via Light Emitting Diodes

    Proline Promass E 100 EtherNet/IP Diagnostics and troubleshooting Content of Web browser incomplete or Not using optimum version of Web 1. Use the correct Web browser version difficult to read server. (® ä 32). 2. Clear the Web browser cache and restart the Web browser.
  • Page 60: Diagnostic Information In The Web Browser

    Diagnostics and troubleshooting Proline Promass E 100 EtherNet/IP 12.3 Diagnostic information in the Web browser 12.3.1 Diagnostic options Any faults detected by the measuring device are displayed in the Web browser on the home page once the user has logged on.
  • Page 61: Calling Up Remedy Information

    Proline Promass E 100 EtherNet/IP Diagnostics and troubleshooting Diagnostic information The fault can be identified using the diagnostic information. The short text helps you by providing information about the fault. Diagnostic information Diagnostic code Status signal Diagnostic number Short text ¯...
  • Page 62: Calling Up Remedy Information

    Diagnostics and troubleshooting Proline Promass E 100 EtherNet/IP 12.4.2 Calling up remedy information Remedy information is provided for every diagnostic event to ensure that problems can be rectified quickly: • On the home page Remedy information is displayed in a separate field below the diagnostics information.
  • Page 63: Overview Of Diagnostic Information

    Proline Promass E 100 EtherNet/IP Diagnostics and troubleshooting Options Description Logbook entry only The device continues to measure. The diagnostic message is entered in the Event logbook (events list) submenu only and is not displayed in alternation with the measured value display.
  • Page 64 Diagnostics and troubleshooting Proline Promass E 100 EtherNet/IP Memory content 1. Reset device. Alarm 2. Contact service. Electronic failure 1. Transfer data or reset device. Alarm 2. Contact service. Data storage 1. Insert DAT module. Alarm 2. Replace DAT module.
  • Page 65: Pending Diagnostic Events

    Proline Promass E 100 EtherNet/IP Diagnostics and troubleshooting Ambient temperature Increase ambient temperature. Warning range Process temperature Reduce process temperature. Warning Process temperature Increase process temperature. Warning Process limit Low flow cut off active! Logbook entry only 1. Check low flow cut off configuration.
  • Page 66: Diagnostic List

    Diagnostics and troubleshooting Proline Promass E 100 EtherNet/IP Actual diagnostics 1 diagnostic event has Displays the current Diagnostic code, short occurred diagnostic event along with message the diagnostic information. If two or more messages occur simultaneously, the message with the highest priority is shown on the display.
  • Page 67: 2Filtering The Event Logbook

    Proline Promass E 100 EtherNet/IP Diagnostics and troubleshooting For filtering the displayed event messages (® ä 67) 12.10.2 Filtering the event logbook Using the Filter options parameter, you can define which category of event messages is displayed in the Events list submenu.
  • Page 68: 12.12 Device Information

    Diagnostics and troubleshooting Proline Promass E 100 EtherNet/IP Navigation path "Diagnostics" menu ® Device reset ® Device reset Function scope of the "Device reset" parameter Options Description Cancel The user exists the parameter and no action is performed. To factory defaults Every parameter is reset to its factory setting.
  • Page 69: 12.13 Disposal

    Proline Promass E 100 EtherNet/IP Diagnostics and troubleshooting Serial number Displays the serial number of Max. 11-digit character the measuring device. string comprising letters and numbers The number can be found on the nameplate of the sensor and transmitter. Firmware version...
  • Page 70: 2Disposing Of The Measuring Device

    Diagnostics and troubleshooting Proline Promass E 100 EtherNet/IP 12.13.2 Disposing of the measuring device WARNING Danger to personnel and environment from fluids that are hazardous to health. Ensure that the measuring device and all cavities are free of fluid residues that are hazardous to ►...
  • Page 71: Repair

    • Spare parts are grouped into logical kits with the associated Installation Instructions. • Repairs are carried out by Endress+Hauser Service or by correspondingly trained customers. • Certified devices can be converted into other certified devices by Endress+Hauser Service or at the factory only.
  • Page 72: Maintenance

    • Observe the maximum permitted fluid temperature for the measuring device (® ä 83). 14.2 Measuring and test equipment Endress+Hauser offers a wide variety of measuring and test equipment, such as W@M or device tests. Your Endress+Hauser Sales Center can provide detailed information on the services.
  • Page 73: Return

    The measuring device must be returned if repairs or a factory calibration are required, or if the wrong measuring device has been ordered or delivered. According to legal regulations, Endress+Hauser, as an ISO-certified company, is required to follow certain procedures when handling returned products that are in contact with medium.
  • Page 74: Disposal

    Disposal Proline Promass E 100 EtherNet/IP Disposal 16.1 Removing the measuring device 1. Switch off the device. 2. WARNING! Danger to persons from process conditions. Beware of hazardous process conditions such as pressure in the measuring device, high temperatures or aggressive fluids.
  • Page 75: Technical Data

    Proline Promass E 100 EtherNet/IP Technical data Technical data 17.1 Application The measuring device is suitable for flow measurement of liquids and gases only. Depending on the version ordered, the measuring device can also measure potentially explosive, flammable, poisonous and oxidizing media.
  • Page 76: Output

    Technical data Proline Promass E 100 EtherNet/IP Maximum full scale value for gas [kg/h] max(G) Maximum full scale value for liquid [kg/h] max(F) < g can never be greater than g max(G) max(F) max(G) max(F) Gas density in [kg/m ] at operating conditions...
  • Page 77 Proline Promass E 100 EtherNet/IP Technical data EtherNet/IP Device diagnostics Device condition can be read out in Input Assembly Web browser Plain text display With information on cause and remedial measures Light emitting diodes (LED) Status information Status indicated by various light emitting diodes The following information is displayed depending on the device version: •...
  • Page 78 Technical data Proline Promass E 100 EtherNet/IP Fix Input Exclusive Owner Multicast Instance Size [Byte] [ms] Instance configuration: 0x68 O ® T configuration: 0x66 T ® O configuration: 0x64 Input only Multicast Instance Size [Byte] [ms] Instance configuration: 0x68 O ® T configuration: 0x67 T ®...
  • Page 79: Power Supply

    Proline Promass E 100 EtherNet/IP Technical data 17.5 Power supply Terminal assignment (® ä 24) Pin assignment, device plug (® ä 24) Supply voltage Transmitter For device version with all communication methods except Modbus RS485 intrinsically safe: DC 20 to 30 V...
  • Page 80: Performance Characteristics

    Technical data Proline Promass E 100 EtherNet/IP 17.6 Performance characteristics Reference operating • Error limits based on ISO 11631 conditions • Water with +15 to +45 °C (+59 to +113 °F) at 2 to 6 bar (29 to 87 psi) •...
  • Page 81 Proline Promass E 100 EtherNet/IP Technical data Design fundamentals (® ä 82) Flow values Flow values as turndown parameter depending on nominal diameter. SI units 1:10 1:20 1:50 1:100 1:500 [mm] [kg/h] [kg/h] [kg/h] [kg/h] [kg/h] [kg/h] 2 000 6 500...
  • Page 82 Technical data Proline Promass E 100 EtherNet/IP Density When there is a difference between the density calibration temperature and the process temperature, the typical measured error of the sensor is ±0.00005 g/cm /°C (±0.000025 g/cm /°F). Field density calibration is possible.
  • Page 83: Installation

    Proline Promass E 100 EtherNet/IP Technical data o.r. = of reading Base accuracy for [% o.r.] Mass flow, liquids Volume flow, liquids Mass flow, gases 0.75 17.7 Installation "Mounting requirements" (® ä 17) 17.8 Environment Ambient temperature range (® ä 19) –40 to +80 °C (–40 to +176 °F), preferably at +20 °C (+68 °F)
  • Page 84: 17.10 Mechanical Construction

    Technical data Proline Promass E 100 EtherNet/IP Pressure-temperature ratings An overview of the material load diagrams (pressure/temperature diagrams) for the process connections is provided in the "Technical Information" document. Secondary containment The sensor housing is filled with dry nitrogen and protects the electronics and mechanics inside.
  • Page 85 Proline Promass E 100 EtherNet/IP Technical data Weight in US units All values (weight) refer to devices with EN/DIN PN 40 flanges. Weight information in [lbs] Weight [lbs] [in] ½ 1 ½ Materials Transmitter housing • Order code for "Housing", option A: aluminum coating AlSi10Mg •...
  • Page 86: 17.11 Operability

    Technical data Proline Promass E 100 EtherNet/IP Sensor housing • Acid and alkali-resistant outer surface • Stainless steel 1.4301/304 Measuring tubes • Stainless steel EN 1.4539 / ASTM 904L • Surface quality: – Ra = 0.8 mm (32 min) – Ra = 0.4 mm (16 min)
  • Page 87: 17.12 Certificates And Approvals

    Directives. These are listed in the corresponding EC Declaration of Conformity along with the standards applied. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. C-Tick symbol The measuring system meets the EMC requirements of the "Australian Communications and Media Authority (ACMA)".
  • Page 88: 17.13 Accessories

    For an overview of the accessories that can be ordered, see the "Technical Information" document 17.14 Documentation The following document types are available: • On the CD-ROM supplied with the device • In the Download Area of the Endress+Hauser Internet site: www.endress.com ® Download Standard documentation Device type: 8E1B**- Communication Document type...
  • Page 89: Appendix

    Proline Promass E 100 EtherNet/IP Appendix Appendix 18.1 Overview of the operating menu The following table provides an overview of the entire operating menu structure with menus and parameters. The page reference indicates where a description of the parameter can be found in the manual.
  • Page 90 Appendix Proline Promass E 100 EtherNet/IP External pressure (® ä 43) Communication ® (® ä 43) MAC address (® ä 43) Default network settings (® ä 43) DHCP client (® ä 43) IP address (® ä 43) Subnet mask (® ä 44) Default gateway (®...
  • Page 91 Proline Promass E 100 EtherNet/IP Appendix Square expansion (® ä 48) coefficient Sensor adjustment ® (® ä 49) Installation direction (® ä 49) ® Zero point adjustment (® ä 49) Zero point adjustment (® ä 49) control Progress (® ä 49) Totalizer 1 to 3 ®...
  • Page 92 Appendix Proline Promass E 100 EtherNet/IP ENP version (® ä 69) IP address (® ä 69) Subnet mask (® ä 69) Default gateway (® ä 69) Measured values ® (® ä 54) Process variables ® (® ä 54) Mass flow (®...
  • Page 93 Proline Promass E 100 EtherNet/IP Appendix Assign behavior of (® ä 63) diagnostic no. 046 Assign behavior of (® ä 63) diagnostic no. 274 Assign behavior of (® ä 64) diagnostic no. 832 Assign behavior of (® ä 65) diagnostic no. 833 Assign behavior of (®...
  • Page 94 Appendix Proline Promass E 100 EtherNet/IP Corrected volume flow unit (® ä 40) Corrected volume unit (® ä 40) Density unit (® ä 40) Reference density unit (® ä 40) Temperature unit (® ä 40) Pressure unit (® ä 40)
  • Page 95 Proline Promass E 100 EtherNet/IP Appendix Pressure shock suppression (® ä 45) ® Partial filled pipe (® ä 46) detection Assign process variable (® ä 46) Low value partial filled pipe (® ä 46) detection High value partial filled pipe (®...
  • Page 96 Appendix Proline Promass E 100 EtherNet/IP Zero point adjustment ® (® ä 49) Zero point adjustment (® ä 49) control Progress (® ä 49) Variable adjust ® Mass flow offset Mass flow factor Volume flow offset Volume flow factor Corrected volume flow...
  • Page 97 Proline Promass E 100 EtherNet/IP Appendix Web server functionality (® ä 34) ® Configurable input assembly Input assembly (® ä 62) position 1 to 20 Application ® Reset all totalizers (® ä 56) ® Totalizer 1 to 3 (® ä 56) Assign process variable (®...
  • Page 98 Appendix Proline Promass E 100 EtherNet/IP ENP version (® ä 69) Configuration counter Min/max values ® Reset min/max values Electronics temperature ® Minimum value Maximum value Medium temperature ® Minimum value Maximum value Carrier pipe temperature ® Minimum value Maximum value Oscillation frequency ®...
  • Page 99: Index

    Proline Promass E 100 EtherNet/IP Index Index Transmitter ......12 Device repair ....... 71 Accuracy .
  • Page 100 Index Proline Promass E 100 EtherNet/IP Exterior cleaning ......72 Materials ........85 Maximum measured error .
  • Page 101 Proline Promass E 100 EtherNet/IP Index Order code ......12, 13 Safety instructions .
  • Page 102 Index Proline Promass E 100 EtherNet/IP Release date ......38 Source ....... . . 38 Version .
  • Page 104 www.endress.com/worldwide BA01064D/06/EN/01.12 71165109 EH-COSIMA ProMoDo...

Table of Contents