Endress+Hauser Proline Promass E 300 HART Operating Instructions Manual

Endress+Hauser Proline Promass E 300 HART Operating Instructions Manual

Coriolis flowmeter
Table of Contents

Advertisement

Quick Links

BA01484D/06/EN/04.21
71505952
2021-01-01
Valid as of version
01.05.zz (Device firmware)
Products
Operating Instructions
Proline Promass E 300
Coriolis flowmeter
HART
Solutions
Services

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser Proline Promass E 300 HART

  • Page 1 Products Solutions Services BA01484D/06/EN/04.21 71505952 2021-01-01 Valid as of version 01.05.zz (Device firmware) Operating Instructions Proline Promass E 300 Coriolis flowmeter HART...
  • Page 2 • The manufacturer reserves the right to modify technical data without prior notice. Your Endress+Hauser Sales Center will supply you with current information and updates to these instructions. Endress+Hauser...
  • Page 3: Table Of Contents

    Proline Promass E 300 HART Table of contents Table of contents About this document ....6 Installation ..... . . 22 Document function .
  • Page 4 Table of contents Proline Promass E 300 HART Access to the operating menu via the Web 10.5.8 Using parameters for device browser ......55 administration .
  • Page 5 13.2 Measuring and test equipment ... 167 13.3 Endress+Hauser services ....167 Repair ......168 14.1 General notes .
  • Page 6: About This Document

    About this document Proline Promass E 300 HART About this document Document function These Operating Instructions contain all the information that is required in various phases of the life cycle of the device: from product identification, incoming acceptance and storage, to mounting, connection, operation and commissioning through to troubleshooting, maintenance and disposal.
  • Page 7: Tool Symbols

    Proline Promass E 300 HART About this document Symbol Meaning Light emitting diode is on. Light emitting diode is flashing. 1.2.4 Tool symbols Symbol Meaning Flat blade screwdriver Allen key Open-ended wrench 1.2.5 Symbols for certain types of information Symbol...
  • Page 8: Documentation

    • W@M Device Viewer (www.endress.com/deviceviewer): Enter the serial number from nameplate • Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the 2D matrix code (QR code) on the nameplate Detailed list of the individual documents along with the documentation code →...
  • Page 9 Proline Promass E 300 HART About this document TRI-CLAMP® Registered trademark of Ladish & Co., Inc., Kenosha, USA Endress+Hauser...
  • Page 10: Safety Instructions

    Safety instructions Proline Promass E 300 HART Safety instructions Requirements for the personnel The personnel for installation, commissioning, diagnostics and maintenance must fulfill the following requirements: ‣ Trained, qualified specialists must have a relevant qualification for this specific function and task.
  • Page 11: Workplace Safety

    Verification for borderline cases: ‣ For special fluids and fluids for cleaning, Endress+Hauser is glad to provide assistance in verifying the corrosion resistance of fluid-wetted materials, but does not accept any warranty or liability as minute changes in the temperature, concentration or level of contamination in the process can alter the corrosion resistance properties.
  • Page 12: Product Safety

    It meets general safety standards and legal requirements. It also complies with the EU directives listed in the device-specific EU Declaration of Conformity. Endress+Hauser confirms this by affixing the CE mark to the device.
  • Page 13: Protecting Access Via A Password

    Proline Promass E 300 HART Safety instructions 2.7.2 Protecting access via a password Different passwords are available to protect write access to the device parameters or access to the device via the WLAN interface. • User-specific access code Protect write access to the device parameters via the local display, Web browser or operating tool (e.g.
  • Page 14: Access Via Opc-Ua

    Safety instructions Proline Promass E 300 HART The device and status information can be hidden on the login page. This prevents unauthorized access to the information. For detailed information on device parameters, see: The "Description of Device Parameters" document →  203.
  • Page 15: Product Description

    Proline Promass E 300 HART Product description Product description The device consists of a transmitter and a sensor. The device is available as a compact version: The transmitter and sensor form a mechanical unit. Product design N ic te r e rg ö...
  • Page 16: Incoming Acceptance And Product

    Is the envelope present with accompanying documents? • If one of the conditions is not satisfied, contact your Endress+Hauser Sales Center. • Depending on the device version, the CD-ROM might not be part of the delivery! The Technical Documentation is available via the Internet or via the Endress+Hauser Operations App, see the "Product identification"...
  • Page 17: Transmitter Nameplate

     8 sections • The W@M Device Viewer: enter the serial number from the nameplate (www.endress.com/deviceviewer) • The Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the 2-D matrix code (QR code) on the nameplate. 4.2.1...
  • Page 18: Sensor Nameplate

    Incoming acceptance and product identification Proline Promass E 300 HART 4.2.2 Sensor nameplate Order code: Ser. no.: Ext. ord. cd.: A0029206  3 Example of a sensor nameplate, part 1 Name of the sensor Manufacturing location Nominal diameter of the sensor; flange nominal diameter/nominal pressure; sensor test pressure; medium temperature range;...
  • Page 19: Symbols On Measuring Device

    Proline Promass E 300 HART Incoming acceptance and product identification 4.2.3 Symbols on measuring device Symbol Meaning WARNING! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury. Reference to documentation Refers to the corresponding device documentation.
  • Page 20: Storage And Transport

    Storage and transport Proline Promass E 300 HART Storage and transport Storage conditions Observe the following notes for storage: ‣ Store in the original packaging to ensure protection from shock. ‣ Do not remove protective covers or protective caps installed on process connections.
  • Page 21: Measuring Devices With Lifting Lugs

    Proline Promass E 300 HART Storage and transport 5.2.2 Measuring devices with lifting lugs CAUTION Special transportation instructions for devices with lifting lugs ‣ Only use the lifting lugs fitted on the device or flanges to transport the device. ‣...
  • Page 22: Installation

    Installation Proline Promass E 300 HART Installation Installation conditions 6.1.1 Mounting position Mounting location A0028772 To prevent measuring errors arising from accumulation of gas bubbles in the measuring tube, avoid the following mounting locations in the pipe: • Highest point of a pipeline.
  • Page 23 Proline Promass E 300 HART Installation Ø orifice plate, pipe restriction [mm] [in] [mm] [in] ³⁄₈ 0.24 ½ 0.40 0.55 1½ 0.87 1.10 1.97 Orientation The direction of the arrow on the sensor nameplate helps you to install the sensor according to the flow direction (direction of medium flow through the piping).
  • Page 24: Environmental And Process Requirements

    If operating outdoors: Avoid direct sunlight, particularly in warm climatic regions. You can order a weather protection cover from Endress+Hauser. →  170. System pressure It is important that cavitation does not occur, or that gases entrained in the liquids do not outgas.
  • Page 25 Proline Promass E 300 HART Installation Thermal insulation In the case of some fluids, it is important to keep the heat radiated from the sensor to the transmitter to a low level. A wide range of materials can be used for the required insulation.
  • Page 26: Special Mounting Instructions

    Installation Proline Promass E 300 HART 6.1.3 Special mounting instructions Drainability The measuring tubes can be completely drained and protected against solids build-up in vertical orientation. Sanitary compatibility • When installing in hygienic applications, please refer to the information in the "Certificates and approvals/hygienic compatibility"...
  • Page 27: Mounting The Measuring Device

    Proline Promass E 300 HART Installation Protective cover 280 (11.0) 255 (10.0) 146 (5.75) 134 (5.3) 12 (0.47) 30 (1.18) A0029553  8 Engineering unit mm (in) Cover locking NOTICE Order code for "Housing", option L "Cast, stainless": The covers of the transmitter housing are provided with a borehole to lock the cover.
  • Page 28: Preparing The Measuring Device

    Installation Proline Promass E 300 HART 6.2.2 Preparing the measuring device 1. Remove all remaining transport packaging. 2. Remove any protective covers or protective caps present from the sensor. 3. If present, remove transport protection of the rupture disk. 4. Remove stick-on label on the electronics compartment cover.
  • Page 29: Turning The Display Module

    Proline Promass E 300 HART Installation 6. Screw on the connection compartment cover. 7. Depending on the device version: Attach the securing clamp of the connection compartment cover. 6.2.5 Turning the display module The display module can be turned to optimize display readability and operability.
  • Page 30: Electrical Connection

    Electrical connection Proline Promass E 300 HART Electrical connection NOTICE The measuring device does not have an internal circuit breaker. ‣ For this reason, assign the measuring device a switch or power-circuit breaker so that the power supply line can be easily disconnected from the mains.
  • Page 31 Proline Promass E 300 HART Electrical connection Relay output Standard installation cable is sufficient. Current input 0/4 to 20 mA Standard installation cable is sufficient. Status input Standard installation cable is sufficient. Cable diameter • Cable glands supplied: M20 × 1.5 with cable ⌀ 6 to 12 mm (0.24 to 0.47 in) •...
  • Page 32 Electrical connection Proline Promass E 300 HART Max. cable length for use in Non-hazardous area, Cross-section Ex Zone 2, Class I, Division 2 Ex Zone 1, Class I, Division 1 0.34 mm (22 AWG) 80 m (270 ft) 0.50 mm...
  • Page 33: Terminal Assignment

    Proline Promass E 300 HART Electrical connection 7.1.3 Terminal assignment Transmitter: supply voltage, input/outputs The terminal assignment of the inputs and outputs depends on the individual order version of the device. The device-specific terminal assignment is documented on an adhesive label in the terminal cover.
  • Page 34 Electrical connection Proline Promass E 300 HART – – – 3 mm A0029813 1. Loosen the securing clamp of the connection compartment cover. 2. Unscrew the connection compartment cover. 3. Squeeze the tabs of the display module holder together. 4. Remove the display module holder.
  • Page 35 Proline Promass E 300 HART Electrical connection 22 mm 24 mm – A0029816 10. Connect the cable in accordance with the terminal assignment .  Signal cable terminal assignment: The device-specific terminal assignment is documented on an adhesive label in the terminal cover.
  • Page 36: Connecting The Remote Display And Operating Module Dkx001

    Electrical connection Proline Promass E 300 HART 7.2.2 Connecting the remote display and operating module DKX001 The remote display and operating module DKX001 is available as an optional extra →  170. • The remote display and operating module DKX001 is only available for the following housing version: order code for "Housing": option A "Aluminum, coated"...
  • Page 37: Special Connection Instructions

    Proline Promass E 300 HART Electrical connection Special connection instructions 7.4.1 Connection examples Current output 4 to 20 mA HART 4...20 mA A0029055  10 Connection example for 4 to 20 mA HART current output (active) Automation system with current input (e.g. PLC) Cable shield provided at one end.
  • Page 38 Electrical connection Proline Promass E 300 HART HART input 4...20 mA A0028763  12 Connection example for HART input with a common negative (passive) Automation system with HART output (e.g. PLC) Active barrier for power supply (e.g. RN221N) Cable shield provided at one end. The cable shield must be grounded at both ends to comply with EMC requirements;...
  • Page 39 Proline Promass E 300 HART Electrical connection Pulse/frequency output 12345 A0028761  15 Connection example for pulse/frequency output (passive) Automation system with pulse/frequency input (e.g. PLC) Power supply Transmitter: Observe input values →  179 Switch output A0028760  16 Connection example for switch output (passive) Automation system with switch input (e.g.
  • Page 40 Electrical connection Proline Promass E 300 HART A0029279  18 Connection example for double pulse output (passive) Automation system with double pulse input (e.g. PLC) Power supply Transmitter: Observe input values →  180 Double pulse output Double pulse output (slave), phase-shifted...
  • Page 41: Ensuring The Degree Of Protection

    Proline Promass E 300 HART Electrical connection Status input A0028764  21 Connection example for status input Automation system with status output (e.g. PLC) Power supply Transmitter Ensuring the degree of protection The measuring device fulfills all the requirements for the IP66/67 degree of protection, Type 4X enclosure.
  • Page 42: Operation Options

    Operation options Proline Promass E 300 HART Operation options Overview of operation options A0034513 Local operation via display module Computer with Web browser (e.g. Internet Explorer) or with operating tool (e.g. FieldCare, DeviceCare, AMS Device Manager, SIMATIC PDM) Field Xpert SFX350 or SFX370...
  • Page 43: Structure And Function Of The Operating Menu

    Proline Promass E 300 HART Operation options Structure and function of the operating menu 8.2.1 Structure of the operating menu For an overview of the operating menu for experts: "Description of Device Parameters" document supplied with the device→  203...
  • Page 44: Operating Philosophy

    Operation options Proline Promass E 300 HART 8.2.2 Operating philosophy The individual parts of the operating menu are assigned to certain user roles (operator, maintenance etc.). Each user role contains typical tasks within the device lifecycle. Menu/parameter User role and tasks...
  • Page 45: Access To The Operating Menu Via The Local Display

    Proline Promass E 300 HART Operation options Access to the operating menu via the local display 8.3.1 Operational display X X X X X X X 1120.50 kg/h A0029348 Operational display Device tag Status area Display area for measured values (4-line) Operating elements→...
  • Page 46: Navigation View

    Operation options Proline Promass E 300 HART • Density • Reference density Temperature Totalizer  The measurement channel number indicates which of the three totalizers is displayed. Output  The measurement channel number indicates which of the outputs is displayed.
  • Page 47 Proline Promass E 300 HART Operation options • In the submenu: Omission symbol for Name of current Display symbol for menu operating menu levels in • Submenu • In the wizard: between • Wizard Display symbol for wizard • Parameters ↓...
  • Page 48: Editing View

    Operation options Proline Promass E 300 HART Locking Symbol Meaning Parameter locked When displayed in front of a parameter name, indicates that the parameter is locked. • By a user-specific access code • By the hardware write protection switch Wizard operation...
  • Page 49 Proline Promass E 300 HART Operation options Text editor Xxxxxxx A B C D E F G H I J K M N O P Q R S T U V W A0034114  24 For entering text in parameters (e.g. tag name)
  • Page 50: Operating Elements

    Operation options Proline Promass E 300 HART Controlling data entries Symbol Meaning Move entry position Reject entry Confirm entry Delete character immediately to the left of the entry position Delete character immediately to the right of the entry position Clear all the characters entered 8.3.4...
  • Page 51: Opening The Context Menu

    Proline Promass E 300 HART Operation options Operating key(s) Meaning Escape key combination (press keys simultaneously) In a menu, submenu • Pressing the key briefly: • Exits the current menu level and takes you to the next higher level. • If help text is open, closes the help text of the parameter.
  • Page 52: Navigating And Selecting From List

    Operation options Proline Promass E 300 HART 8.3.6 Navigating and selecting from list Different operating elements are used to navigate through the operating menu. The navigation path is displayed on the left in the header. Icons are displayed in front of the individual menus.
  • Page 53: Calling Up Help Text

    Proline Promass E 300 HART Operation options The direct access code consists of a 5-digit number (at maximum) and the channel number, which identifies the channel of a process variable: e.g. 00914-2. In the navigation view, this appears on the right-hand side in the header of the selected parameter.
  • Page 54: User Roles And Related Access Authorization

    Operation options Proline Promass E 300 HART Ent. access code Invalid or out of range input value Min:0 Max:9999 A0014049-EN For a description of the editing view - consisting of the text editor and numeric editor - with symbols →  48, for a description of the operating elements →  50 8.3.10...
  • Page 55: Enabling And Disabling The Keypad Lock

    Proline Promass E 300 HART Operation options 2. Enter the access code.  The -symbol in front of the parameters disappears; all previously write- protected parameters are now re-enabled. 8.3.12 Enabling and disabling the keypad lock The keypad lock makes it possible to block access to the entire operating menu via local operation.
  • Page 56: Prerequisites

    Operation options Proline Promass E 300 HART 8.4.2 Prerequisites Computer hardware Hardware Interface CDI-RJ45 WLAN Interface The computer must have an RJ45 The operating unit must have a interface. WLAN interface. Connection Standard Ethernet cable with RJ45 Connection via Wireless LAN.
  • Page 57: Establishing A Connection

    Proline Promass E 300 HART Operation options Measuring device: Via CDI-RJ45 service interface Device CDI-RJ45 service interface Measuring device The measuring device has an RJ45 interface. Web server Web server must be enabled; factory setting: ON  For information on enabling the Web server →  61...
  • Page 58 Operation options Proline Promass E 300 HART Via WLAN interface Configuring the Internet protocol of the mobile terminal NOTICE If the WLAN connection is lost during the configuration, settings made may be lost. ‣ Make sure that the WLAN connection is not disconnected while configuring the device.
  • Page 59: Logging On

    Proline Promass E 300 HART Operation options 2. Enter the IP address of the Web server in the address line of the Web browser: 192.168.1.212  The login page appears. 2 3 4 A0029417 Picture of device Device name Device tag (→  79)
  • Page 60: User Interface

    Operation options Proline Promass E 300 HART 8.4.5 User interface A0029418 Function row Local display language Navigation area Header The following information appears in the header: • Device name • Device tag • Device status with status signal →  150 •...
  • Page 61: Disabling The Web Server

    Proline Promass E 300 HART Operation options Working area Depending on the selected function and the related submenus, various actions can be performed in this area: • Configuring parameters • Reading measured values • Calling up help text • Starting an upload/download 8.4.6...
  • Page 62: Access To The Operating Menu Via The Operating Tool

    Operation options Proline Promass E 300 HART Access to the operating menu via the operating tool The structure of the operating menu in the operating tools is the same as for operation via the local display. 8.5.1 Connecting the operating tool Via HART protocol This communication interface is available in device versions with a HART output.
  • Page 63 Proline Promass E 300 HART Operation options A0028746  27 Options for remote operation via HART protocol (passive) Control system (e.g. PLC) Transmitter power supply unit, e.g. RN221N (with communication resistor) Connection for Commubox FXA195 and Field Communicator 475 Field Communicator 475 Computer with Web browser (e.g.
  • Page 64 Operation options Proline Promass E 300 HART Via WLAN interface The optional WLAN interface is available on the following device version: Order code for "Display; operation", option G "4-line, illuminated; touch control + WLAN" A0034570 Transmitter with integrated WLAN antenna...
  • Page 65: Field Xpert Sfx350, Sfx370

    FieldCare Function scope FDT-based plant asset management tool from Endress+Hauser. It can configure all smart field devices in a system and helps you manage them. By using the status information, it is also a simple but effective way of checking their status and condition.
  • Page 66 Operation options Proline Promass E 300 HART Access is via: • HART protocol • CDI-RJ45 service interface →  63 • WLAN interface→  64 Typical functions: • Configuring parameters of transmitters • Loading and saving device data (upload/download) • Documentation of the measuring point •...
  • Page 67: Devicecare

    DeviceCare Function scope Tool to connect and configure Endress+Hauser field devices. The fastest way to configure Endress+Hauser field devices is with the dedicated "DeviceCare" tool. Together with the device type managers (DTMs) it presents a convenient, comprehensive solution. For details, see Innovation Brochure IN01047S Source for device description files See information →...
  • Page 68: Simatic Pdm

    Operation options Proline Promass E 300 HART Source for device description files See data →  69 8.5.6 SIMATIC PDM Function scope SIMATIC PDM is a standardized, manufacturer-independent program from Siemens for the operation, configuration, maintenance and diagnosis of intelligent field devices via HART protocol.
  • Page 69: System Integration

    Proline Promass E 300 HART System integration System integration Overview of device description files 9.1.1 Current version data for the device Firmware version 01.05.zz • On the title page of the Operating Instructions • On the transmitter nameplate • Firmware version Diagnostics →...
  • Page 70: Measured Variables Via Hart Protocol

    System integration Proline Promass E 300 HART Measured variables via HART protocol The following measured variables (HART device variables) are assigned to the dynamic variables at the factory: Dynamic variables Measured variables (HART device variables) Primary dynamic variable (PV) Mass flow...
  • Page 71 Proline Promass E 300 HART System integration Measured variables for PV (primary dynamic variable) • Measured variables which are generally available: • Mass flow • Volume flow • Corrected volume flow • Density • Reference density • Temperature • Electronic temperature •...
  • Page 72: Device Variables

    System integration Proline Promass E 300 HART Measured variables for SV, TV, QV (secondary, tertiary and quaternary dynamic variable) • Measured variables which are always available: • Mass flow • Volume flow • Corrected volume flow • Density • Reference density •...
  • Page 73 Proline Promass E 300 HART System integration Assignment Device variables Totalizer 1 Totalizer 2 Totalizer 3 Target mass flow Carrier mass flow Concentration Visible depending on the order options or device settings Endress+Hauser...
  • Page 74: Other Settings

    System integration Proline Promass E 300 HART Other settings Burst mode functionality in accordance with HART 7 Specification: Navigation "Expert" menu → Communication → HART output → Burst configuration → Burst configuration 1 to n ‣ Burst configuration ‣ Burst configuration 1 to n Burst mode 1 to n →...
  • Page 75 Proline Promass E 300 HART System integration Parameter Description Selection / User entry Burst variable 0 For HART command 9 and 33: select the HART device variable • Mass flow or the process variable. • Volume flow • Corrected volume flow • Target mass flow •...
  • Page 76 System integration Proline Promass E 300 HART Parameter Description Selection / User entry Min. update period Enter the minimum time span between two burst commands of Positive integer burst message X. Max. update period Enter the maximum time span between two burst commands of Positive integer burst message X.
  • Page 77: Commissioning

    Proline Promass E 300 HART Commissioning Commissioning 10.1 Function check Before commissioning the measuring device: ‣ Make sure that the post-installation and post-connection checks have been performed. • "Post-installation check" checklist→  29 • "Post-connection check" checklist →  41 10.2...
  • Page 78 Commissioning Proline Promass E 300 HART X X X X X X X 20.50 0104-1 Main menu Display language English Display/operat. Setup Main menu Display/operat. Setup Diagnostic / ../Setup Medium selection XXXXXXXXX XXXXXXXXX A0032222-EN  30 Taking the example of the local display The number of submenus and parameters can vary depending on the device version.
  • Page 79: Defining The Tag Name

    Proline Promass E 300 HART Commissioning ‣ Partially filled pipe detection →  109 ‣ Advanced setup →  110 10.4.1 Defining the tag name To enable fast identification of the measuring point within the system, you can enter a unique designation using the Device tag parameter and thus change the factory setting.
  • Page 80 Commissioning Proline Promass E 300 HART Corrected volume flow unit →  80 Corrected volume unit →  80 →  80 Density unit Reference density unit →  80 Temperature unit →  81 Pressure unit →  81...
  • Page 81 Proline Promass E 300 HART Commissioning Parameter Description Selection Factory setting Temperature unit Select temperature unit. Unit choose list Country-specific: • °C Result • °F The selected unit applies for: • Electronic temperature parameter (6053) • Maximum value parameter (6051) •...
  • Page 82: Selecting And Setting The Medium

    Commissioning Proline Promass E 300 HART 10.4.3 Selecting and setting the medium The Select medium wizard submenu contains parameters that must be configured in order to select and set the medium. Navigation "Setup" menu → Select medium ‣ Medium selection Select medium →...
  • Page 83: Displaying The I/O Configuration

    Proline Promass E 300 HART Commissioning Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry / User interface Select medium – Select medium type. • Liquid – • Gas Select gas type The Gas option is selected in Select measured gas type.
  • Page 84: Configuring The Current Input

    Commissioning Proline Promass E 300 HART Navigation "Setup" menu → I/O configuration ‣ I/O configuration I/O module 1 to n terminal numbers →  84 I/O module 1 to n information →  84 →  84 I/O module 1 to n type Apply I/O configuration →...
  • Page 85: Configuring The Status Input

    Proline Promass E 300 HART Commissioning Signal mode →  85 0/4 mA value →  85 →  85 20 mA value Current span →  85 Failure mode →  85 Failure value →  85 Parameter overview with brief description...
  • Page 86: Configuring The Current Output

    Commissioning Proline Promass E 300 HART Navigation "Setup" menu → Status input ‣ Status input 1 to n Assign status input →  86 Terminal number →  86 →  86 Active level Terminal number →  86 Response time status input →...
  • Page 87 Proline Promass E 300 HART Commissioning Current span →  89 0/4 mA value →  89 →  89 20 mA value Fixed current →  89 Damping output 1 to n →  89 Failure mode →  89 →...
  • Page 88 Commissioning Proline Promass E 300 HART Parameter Prerequisite Description User interface /  Factory setting Selection / User entry Assign current output 1 to n – Select process variable for • Off – current output. • Mass flow • Volume flow • Corrected volume flow •...
  • Page 89 Proline Promass E 300 HART Commissioning Parameter Prerequisite Description User interface /  Factory setting Selection / User entry Current span – Select current range for • 4...20 mA NAMUR Country-specific: process value output and (3.8...20.5 mA) • 4...20 mA NAMUR upper/lower level for alarm •...
  • Page 90: Configuring The Pulse/Frequency

    Commissioning Proline Promass E 300 HART 10.4.8 Configuring the pulse/frequency/switch output The Pulse/frequency/switch output wizard guides you systematically through all the parameters that can be set for configuring the selected output type. Navigation "Setup" menu → Advanced setup → Pulse/frequency/switch output ‣...
  • Page 91 Proline Promass E 300 HART Commissioning Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting interface / User entry Operating mode – Define the output as a pulse, • Pulse – frequency or switch output. • Frequency • Switch Terminal number –...
  • Page 92 Commissioning Proline Promass E 300 HART Parameter Prerequisite Description Selection / User Factory setting interface / User entry Failure mode The Pulse option is selected in Define output behavior in • Actual value – the Operating mode alarm condition. • No pulses parameter (→  90) and a...
  • Page 93 Proline Promass E 300 HART Commissioning Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting interface / User entry Operating mode – Define the output as a pulse, • Pulse – frequency or switch output. • Frequency • Switch Terminal number –...
  • Page 94 Commissioning Proline Promass E 300 HART Parameter Prerequisite Description Selection / User Factory setting interface / User entry Assign frequency output The Frequency option is Select process variable for • Off – selected in the Operating frequency output. • Mass flow mode parameter (→  90).
  • Page 95 Proline Promass E 300 HART Commissioning Parameter Prerequisite Description Selection / User Factory setting interface / User entry Minimum frequency value The Frequency option is Enter minimum frequency. 0.0 to 10 000.0 Hz – selected in the Operating mode parameter (→  90) and a process variable is...
  • Page 96 Commissioning Proline Promass E 300 HART Configuring the switch output Navigation "Setup" menu → Pulse/frequency/switch output ‣ Pulse/frequency/switch output 1 to n Operating mode →  96 Terminal number →  96 Signal mode →  96 Switch output function →...
  • Page 97 Proline Promass E 300 HART Commissioning Parameter Prerequisite Description Selection / User Factory setting interface / User entry Switch output function The Switch option is selected Select function for switch • Off – in the Operating mode output. • On parameter. • Diagnostic behavior •...
  • Page 98 Commissioning Proline Promass E 300 HART Parameter Prerequisite Description Selection / User Factory setting interface / User entry Assign limit • The Switch option is Select process variable for limit • Mass flow – selected in the Operating function. • Volume flow mode parameter.
  • Page 99: Configuring The Relay Output

    Proline Promass E 300 HART Commissioning Parameter Prerequisite Description Selection / User Factory setting interface / User entry Assign status • The Switch option is Select device status for switch • Partially filled pipe – selected in the Operating output. detection mode parameter. • Low flow cut off •...
  • Page 100 Commissioning Proline Promass E 300 HART Assign status →  101 Switch-off value →  101 →  102 Switch-on value Failure mode →  102 Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting interface / User entry Relay output function –...
  • Page 101 Proline Promass E 300 HART Commissioning Parameter Prerequisite Description Selection / User Factory setting interface / User entry Assign limit The Limit option is selected in Select process variable for limit • Mass flow – the Relay output function function. • Volume flow parameter.
  • Page 102: 10.4.10 Configuring The Double Pulse Output

    Commissioning Proline Promass E 300 HART Parameter Prerequisite Description Selection / User Factory setting interface / User entry Switch-off delay In the Relay output function Define delay for the switch-off 0.0 to 100.0 s – parameter, the Limit option is of status output. selected.
  • Page 103: 10.4.11 Configuring The Local Display

    Proline Promass E 300 HART Commissioning Parameter overview with brief description Parameter Description Selection / User interface /  Factory setting User entry Signal mode Select the signal mode for the double pulse • Passive – output. • Active • Passive NAMUR Master terminal number Shows the terminal numbers used by the •...
  • Page 104 Commissioning Proline Promass E 300 HART Navigation "Setup" menu → Display ‣ Display Format display →  105 Value 1 display →  106 →  107 0% bargraph value 1 100% bargraph value 1 →  107 Value 2 display →...
  • Page 105 Proline Promass E 300 HART Commissioning Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry Format display A local display is provided. Select how measured values • 1 value, max. size – are shown on the display.
  • Page 106 Commissioning Proline Promass E 300 HART Parameter Prerequisite Description Selection / User Factory setting entry Value 1 display A local display is provided. Select the measured value that • Mass flow – is shown on the local display. • Volume flow • Corrected volume flow •...
  • Page 107 Proline Promass E 300 HART Commissioning Parameter Prerequisite Description Selection / User Factory setting entry • Index inhomogeneous medium • Application specific output 0 • Index suspended bubbles 0% bargraph value 1 A local display is provided. Enter 0% value for bar graph...
  • Page 108: 10.4.12 Configuring The Low Flow Cut Off

    Commissioning Proline Promass E 300 HART 10.4.12 Configuring the low flow cut off The Low flow cut off wizard systematically guides the user through all the parameters that must be set to configure low flow cut off. Navigation "Setup" menu → Low flow cut off ‣...
  • Page 109: 10.4.13 Configuring The Partial Filled Pipe Detection

    Proline Promass E 300 HART Commissioning 10.4.13 Configuring the partial filled pipe detection The Partial filled pipe detection wizard guides you systematically through all parameters that have to be set for configuring the monitoring of the pipe filling. Navigation "Setup" menu → Partially filled pipe detection ‣...
  • Page 110: Advanced Settings

    Commissioning Proline Promass E 300 HART 10.5 Advanced settings The Advanced setup submenu together with its submenus contains parameters for specific settings. Navigation to the "Advanced setup" submenu X X X X X X X 20.50 0104-1 Main menu Display language English Display/operat.
  • Page 111: Using The Parameter To Enter The Access Code

    Proline Promass E 300 HART Commissioning ‣ SIL confirmation ‣ Deactivate SIL ‣ →  116 Display ‣ WLAN settings →  120 ‣ Concentration ‣ Heartbeat setup ‣ →  122 Configuration backup ‣ Administration →  123 10.5.1...
  • Page 112: Carrying Out A Sensor Adjustment

    Commissioning Proline Promass E 300 HART Linear expansion coefficient →  112 Square expansion coefficient →  112 Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting interface / User entry Corrected volume flow calculation – Select reference density for •...
  • Page 113: Configuring The Totalizer

    Proline Promass E 300 HART Commissioning Navigation "Setup" menu → Advanced setup → Sensor adjustment ‣ Sensor adjustment Installation direction →  113 ‣ Zero point adjustment →  113 Parameter overview with brief description Parameter Description Selection Installation direction Set sign of flow direction to match the direction of the arrow on •...
  • Page 114 Commissioning Proline Promass E 300 HART Navigation "Setup" menu → Advanced setup → Totalizer 1 to n ‣ Totalizer 1 to n Assign process variable →  114 Unit totalizer 1 to n →  114 →  115 Totalizer operation mode Failure mode →...
  • Page 115 Proline Promass E 300 HART Commissioning Parameter Prerequisite Description Selection Factory setting Totalizer operation mode A process variable is selected Select totalizer calculation • Net flow total – in the Assign process variable mode. • Forward flow total parameter (→  114) of the •...
  • Page 116: Carrying Out Additional Display Configurations

    Commissioning Proline Promass E 300 HART 10.5.5 Carrying out additional display configurations In the Display submenu you can set all the parameters associated with the configuration of the local display. Navigation "Setup" menu → Advanced setup → Display ‣ Display Format display →...
  • Page 117 Proline Promass E 300 HART Commissioning Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry Format display A local display is provided. Select how measured values • 1 value, max. size – are shown on the display.
  • Page 118 Commissioning Proline Promass E 300 HART Parameter Prerequisite Description Selection / User Factory setting entry Value 1 display A local display is provided. Select the measured value that • Mass flow – is shown on the local display. • Volume flow • Corrected volume flow •...
  • Page 119 Proline Promass E 300 HART Commissioning Parameter Prerequisite Description Selection / User Factory setting entry • Index inhomogeneous medium • Application specific output 0 • Index suspended bubbles 0% bargraph value 1 A local display is provided. Enter 0% value for bar graph...
  • Page 120: Wlan Configuration

    Commissioning Proline Promass E 300 HART Parameter Prerequisite Description Selection / User Factory setting entry Display language A local display is provided. Set display language. • English English • Deutsch (alternatively, the • Français ordered language is • Español preset in the device) •...
  • Page 121 Proline Promass E 300 HART Commissioning Navigation "Setup" menu → Advanced setup → WLAN Settings ‣ WLAN settings WLAN IP address →  121 Security type →  121 →  121 WLAN passphrase Assign SSID name →  121 SSID name →...
  • Page 122: Configuration Management

    Commissioning Proline Promass E 300 HART 10.5.7 Configuration management After commissioning, you can save the current device configurationor restore the previous device configuration. You can do so using the Configuration management parameter and the related options found in the Configuration backup submenu.
  • Page 123: Using Parameters For Device Administration

    Proline Promass E 300 HART Commissioning Function scope of the "Configuration management" parameter Options Description Cancel No action is executed and the user exits the parameter. Execute backup A backup copy of the current device configuration is saved from the HistoROM backup to the memory of the device.
  • Page 124: Simulation

    Reset access code to factory settings. Character string comprising numbers, letters and special characters  For a reset code, contact your Endress+Hauser service organization. The reset code can only be entered via: • Web browser • DeviceCare, FieldCare (via service interface CDI-RJ45) •...
  • Page 125 Proline Promass E 300 HART Commissioning Navigation "Diagnostics" menu → Simulation ‣ Simulation Assign simulation process variable →  126 Process variable value →  126 →  126 Status input simulation 1 to n Input signal level 1 to n →...
  • Page 126 Commissioning Proline Promass E 300 HART Parameter overview with brief description Parameter Prerequisite Description Selection / User entry /  User interface Assign simulation process variable – Select a process variable for the • Off simulation process that is activated. • Mass flow • Volume flow •...
  • Page 127: Protecting Settings From Unauthorized Access

    Proline Promass E 300 HART Commissioning Parameter Prerequisite Description Selection / User entry /  User interface Pulse output simulation 1 to n In the Operating mode parameter, the Set and switch off the pulse output • Off Pulse option is selected. simulation. • Fixed value •...
  • Page 128: Write Protection Via Access Code

    Commissioning Proline Promass E 300 HART 10.7.1 Write protection via access code The effects of the user-specific access code are as follows: • Via local operation, the parameters for the measuring device configuration are write- protected and their values can no longer be changed.
  • Page 129: Write Protection Via Write Protection

    Via Web browser, FieldCare, DeviceCare (via CDI-RJ45 service interface), fieldbus For a reset code, contact your Endress+Hauser service organization. 1. Navigate to the Reset access code parameter (→  124). 2. Enter the reset code.
  • Page 130 Commissioning Proline Promass E 300 HART A0029630 Setting the write protection (WP) switch on the main electronics module to the ON position enables hardware write protection.  In the Locking status parameter the Hardware locked option is displayed →  131. In addition, on the local display the -symbol appears in front of the parameters in the header of the operational display and in the navigation view.
  • Page 131: Operation

    Proline Promass E 300 HART Operation Operation 11.1 Reading the device locking status Device active write protection: Locking status parameter Operation → Locking status Function scope of the "Locking status" parameter Options Description None The access status displayed in the Access status parameter applies →  54. Only appears on local display.
  • Page 132: Measured Variables" Submenu

    Operation Proline Promass E 300 HART 11.4.1 "Measured variables" submenu The Measured variables submenu contains all the parameters needed to display the current measured values for each process variable. Navigation "Diagnostics" menu → Measured values → Measured variables ‣ Measured variables Mass flow →...
  • Page 133: Totalizer" Submenu

    Proline Promass E 300 HART Operation Parameter Prerequisite Description User interface Reference density – Displays the reference density that is Signed floating-point currently calculated. number Dependency The unit is taken from the Reference density unit parameter (→  80). Temperature –...
  • Page 134: Input Values" Submenu

    Operation Proline Promass E 300 HART Parameter overview with brief description Parameter Prerequisite Description User interface Totalizer value 1 to n A process variable is selected in the Displays the current totalizer counter Signed floating-point Assign process variable parameter value.
  • Page 135: Output Values

    Proline Promass E 300 HART Operation Navigation "Diagnostics" menu → Measured values → Input values → Status input 1 to n ‣ Status input 1 to n Value status input →  135 Parameter overview with brief description Parameter Description...
  • Page 136 Operation Proline Promass E 300 HART Parameter overview with brief description Parameter Description User interface Output current 1 Displays the current value currently calculated for the current 3.59 to 22.5 mA output. Measured current Displays the current value currently measured for the current 0 to 30 mA output.
  • Page 137: Adapting The Measuring Device To The Process

    Proline Promass E 300 HART Operation Parameter overview with brief description Parameter Description User interface Switch status Shows the current relay switch status. • Open • Closed Switch cycles Shows number of all performed switch cycles. Positive integer Max. switch cycles number Shows the maximal number of guaranteed switch cycles.
  • Page 138: Function Scope Of The "Control Totalizer" Parameter

    Operation Proline Promass E 300 HART Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry Control Totalizer 1 to n A process variable is selected Control totalizer value. • Totalize – in the Assign process variable • Reset + hold parameter (→...
  • Page 139 Proline Promass E 300 HART Operation Function range • A total of 1000 measured values can be stored • 4 logging channels • Adjustable logging interval for data logging • Displays the measured value trend for each logging channel in the form of a chart / ../XXXXXXXX...
  • Page 140 Operation Proline Promass E 300 HART ‣ Display channel 2 ‣ Display channel 3 ‣ Display channel 4 Endress+Hauser...
  • Page 141 Proline Promass E 300 HART Operation Parameter overview with brief description Parameter Prerequisite Description Selection / User entry /  User interface Assign channel 1 The Extended HistoROM application Assign process variable to logging • Off package is available. channel. • Mass flow • Volume flow •...
  • Page 142 Operation Proline Promass E 300 HART Parameter Prerequisite Description Selection / User entry /  User interface Assign channel 3 The Extended HistoROM application Assign process variable to logging Picklist, see Assign package is available. channel. channel 1 parameter (→  141)  The software options currently...
  • Page 143: Diagnostics And Troubleshooting

    Proline Promass E 300 HART Diagnostics and troubleshooting Diagnostics and troubleshooting 12.1 General troubleshooting For local display Error Possible causes Solution Local display dark and no output Supply voltage does not match the Apply the correct supply voltage signals value indicated on the nameplate.
  • Page 144 Diagnostics and troubleshooting Proline Promass E 300 HART Error Possible causes Solution Device shows correct value on local Configuration error Check and correct the parameter display, but signal output is configuration. incorrect, though in the valid range. Device measures incorrectly.
  • Page 145: Diagnostic Information Via Light Emitting

    Proline Promass E 300 HART Diagnostics and troubleshooting Error Possible causes Solution Parallel WLAN and Ethernet • Check network settings. communication • Temporarily enable only the WLAN as an interface. Web browser frozen and operation Data transfer active Wait until data transfer or current no longer possible action is finished.
  • Page 146 Diagnostics and troubleshooting Proline Promass E 300 HART Color Meaning Device status (normal Firmware error operation) Green Device status is ok. Flashing green Device is not configured. A diagnostic event with "Alarm" diagnostic behavior has occurred. Flashing red A diagnostic event with "Warning" diagnostic behavior has occurred.
  • Page 147: Diagnostic Information On Local Display

    Proline Promass E 300 HART Diagnostics and troubleshooting 12.3 Diagnostic information on local display 12.3.1 Diagnostic message Faults detected by the self-monitoring system of the measuring device are displayed as a diagnostic message in alternation with the operational display. Operational display in alarm condition...
  • Page 148 Diagnostics and troubleshooting Proline Promass E 300 HART Diagnostic behavior Symbol Meaning Alarm • Measurement is interrupted. • Signal outputs and totalizers assume the defined alarm condition. • A diagnostic message is generated. Warning Measurement is resumed. The signal outputs and totalizers are not affected. A diagnostic message is generated.
  • Page 149: Calling Up Remedial Measures

    Proline Promass E 300 HART Diagnostics and troubleshooting 12.3.2 Calling up remedial measures X X X X X X X X X X X X X X 20.50 S801 Supply voltage Menu Diagnostic list Diagnostics 1 S801 Supply voltage Diagnostics 2...
  • Page 150: Calling Up Remedy Information

    Diagnostics and troubleshooting Proline Promass E 300 HART A0031056 Status area with status signal Diagnostic information Remedy information with Service ID In addition, diagnostic events which have occurred can be shown in the Diagnostics menu: • Via parameter →  157 •...
  • Page 151: Diagnostic Information In Fieldcare Or

    Proline Promass E 300 HART Diagnostics and troubleshooting 12.5 Diagnostic information in FieldCare or DeviceCare 12.5.1 Diagnostic options Any faults detected by the measuring device are displayed on the home page of the operating tool once the connection has been established.
  • Page 152: Calling Up Remedy Information

    Diagnostics and troubleshooting Proline Promass E 300 HART 12.5.2 Calling up remedy information Remedy information is provided for every diagnostic event to ensure that problems can be rectified quickly: • On the home page Remedy information is displayed in a separate field below the diagnostics information.
  • Page 153: Overview Of Diagnostic Information

    Proline Promass E 300 HART Diagnostics and troubleshooting Available status signals Configuration as per HART 7 Specification (Condensed Status), in accordance with NAMUR NE107. Symbol Meaning Failure A device error is present. The measured value is no longer valid. A0013956 Function check The device is in service mode (e.g.
  • Page 154 Diagnostics and troubleshooting Proline Promass E 300 HART Diagnostic Short text Remedy instructions Status Diagnostic number signal behavior [from the [from the factory] factory] Sensor signal 1. Check or replace sensor electronic Alarm asymmetrical module (ISEM) 2. If available: Check connection cable between sensor and transmitter 3.
  • Page 155 Proline Promass E 300 HART Diagnostics and troubleshooting Diagnostic Short text Remedy instructions Status Diagnostic number signal behavior [from the [from the factory] factory] Sensor electronic (ISEM) 1. Restart device Alarm faulty 2. Check if failure recurs 3. Replace sensor electronic module...
  • Page 156 Diagnostics and troubleshooting Proline Promass E 300 HART Diagnostic Short text Remedy instructions Status Diagnostic number signal behavior [from the [from the factory] factory] Current input 1 to n Deactivate simulation Warning simulation Current output 1 to n Deactivate simulation...
  • Page 157: Pending Diagnostic Events

    Proline Promass E 300 HART Diagnostics and troubleshooting Diagnostic Short text Remedy instructions Status Diagnostic number signal behavior [from the [from the factory] factory] Sensor temperature too Increase ambient temp. around the Warning sensor housing Electronic temperature Reduce ambient temperature...
  • Page 158: Diagnostic List

    Diagnostics and troubleshooting Proline Promass E 300 HART Navigation "Diagnostics" menu  Diagnostics Actual diagnostics →  158 Previous diagnostics →  158 →  158 Operating time from restart Operating time →  158 Parameter overview with brief description...
  • Page 159: 12.10 Event Logbook

    Proline Promass E 300 HART Diagnostics and troubleshooting / ../Diagnose list Diagnostics F273 Main electronic Diagnostics 2 Diagnostics 3 A0014006-EN  35 Taking the example of the local display To call up the measures to rectify a diagnostic event: • Via local display →  149 •...
  • Page 160: 12.10.2 Filtering The Event Logbook

    Diagnostics and troubleshooting Proline Promass E 300 HART 12.10.2 Filtering the event logbook Using the Filter options parameter you can define which category of event message is displayed in the Events list submenu. Navigation path Diagnostics → Event logbook → Filter options Filter categories •...
  • Page 161: 12.11 Resetting The Measuring Device

    Proline Promass E 300 HART Diagnostics and troubleshooting Info number Info name I1451 Monitoring on I1457 Measurement error verification failed I1459 I/O module verification failed I1460 HBSI verification failed I1461 Sensor verification failed I1462 Sensor electronic module verific. failed I1512...
  • Page 162: 12.11.1 Function Scope Of The "Device Reset" Parameter

    Diagnostics and troubleshooting Proline Promass E 300 HART 12.11.1 Function scope of the "Device reset" parameter Options Description Cancel No action is executed and the user exits the parameter. To delivery settings Every parameter for which a customer-specific default setting was ordered is reset to this customer-specific value.
  • Page 163 Proline Promass E 300 HART Diagnostics and troubleshooting Device type →  163 Manufacturer ID →  163 Parameter overview with brief description Parameter Description User interface Factory setting Device tag Shows name of measuring point. Max. 32 characters, such as –...
  • Page 164: 12.13 Firmware History

    Diagnostics and troubleshooting Proline Promass E 300 HART 12.13 Firmware history Release Firmware Order code for Firmware Documentation Documentation date version "Firmware changes type version" 09.2019 01.05.zz Option 66 • Gas Fraction Operating BA01484D/06/EN/03.19 Handler Instructions Adaptive Filter, Gas Entrainment Index •...
  • Page 165 Proline Promass E 300 HART Diagnostics and troubleshooting Release Firmware Order code for Firmware Documentation Documentation date version "Firmware changes type version" 10.2017 01.01.zz Option 71 • Petroleum new Operating BA01484D/06/EN/02.17 • Concentration Instructions update • OPC-UA with Security new •...
  • Page 166: 12.14 Device History And Compatibility

    "Manufacturer' s information" document. The manufacturer' s information is available: • In the Download Area of the Endress+Hauser web site: www.endress.com → Downloads • Specify the following details: •...
  • Page 167: Maintenance

    →  189. 13.2 Measuring and test equipment Endress+Hauser offers a wide variety of measuring and test equipment, such as W@M or device tests. Your Endress+Hauser Sales Center can provide detailed information on the services. List of some of the measuring and testing equipment: →  170→  172 13.3...
  • Page 168: Repair

    • The measuring devices have a modular design. • Spare parts are grouped into logical kits with the associated Installation Instructions. • Repairs are carried out by Endress+Hauser Service or by appropriately trained customers. • Certified devices can only be converted to other certified devices by Endress+Hauser Service or at the factory.
  • Page 169: Disposal

    (WEEE), the product is marked with the depicted symbol in order to minimize the disposal of WEEE as unsorted municipal waste. Do not dispose of products bearing this marking as unsorted municipal waste. Instead, return them to Endress+Hauser for disposal under the applicable conditions.
  • Page 170: Accessories

    Various accessories, which can be ordered with the device or subsequently from Endress +Hauser, are available for the device. Detailed information on the order code in question is available from your local Endress+Hauser sales center or on the product page of the Endress+Hauser website: www.endress.com.
  • Page 171: For The Sensor

     If using oil as a heating medium, please consult with Endress+Hauser. Heating jackets cannot be used with sensors fitted with a rupture disk. • If ordered together with the measuring device: order code for "Enclosed accessories"...
  • Page 172: Service-Specific Accessories

    Accessories Description Applicator Software for selecting and sizing Endress+Hauser measuring devices: • Choice of measuring devices for industrial requirements • Calculation of all the necessary data for identifying the optimum flowmeter: e.g. nominal diameter, pressure loss, flow velocity and accuracy.
  • Page 173: Technical Data

    Proline Promass E 300 HART Technical data Technical data 16.1 Application The measuring device is intended only for the flow measurement of liquids and gases. Depending on the version ordered, the measuring device can also measure potentially explosive, flammable, poisonous and oxidizing media.
  • Page 174: Input

    Technical data Proline Promass E 300 HART 16.3 Input Measured variable Direct measured variables • Mass flow • Density • Temperature Calculated measured variables • Volume flow • Corrected volume flow • Reference density Measuring range Measuring range for liquids Measuring range full scale values ...
  • Page 175 • Operating pressure to increase accuracy (Endress+Hauser recommends the use of a pressure measuring device for absolute pressure, e.g. Cerabar M or Cerabar S) •...
  • Page 176 Technical data Proline Promass E 300 HART Status input Maximum input values • DC –3 to 30 V • If status input is active (ON): R >3 kΩ Response time Configurable: 5 to 200 ms Input signal level • Low signal: DC –3 to +5 V •...
  • Page 177: Output

    Proline Promass E 300 HART Technical data 16.4 Output Output signal Current output 4 to 20 mA HART Order code "Output; input 1" (20): Option BA: current output 4 to 20 mA HART Signal mode Can be set to: • Active •...
  • Page 178 Technical data Proline Promass E 300 HART Damping Configurable: 0 to 999.9 s Assignable measured • Mass flow variables • Volume flow • Corrected volume flow • Density • Reference density • Temperature • Electronics temperature • Oscillation frequency 0 •...
  • Page 179 Proline Promass E 300 HART Technical data Maximum output values 22.5 mA Maximum input voltage DC 30 V Load 0 to 700 Ω Resolution 0.38 µA Damping Configurable: 0 to 999 s Assignable measured • Mass flow variables • Volume flow •...
  • Page 180 Technical data Proline Promass E 300 HART Assignable measured • Mass flow variables • Volume flow • Corrected volume flow • Density • Reference density • Temperature • Electronics temperature • Oscillation frequency 0 • Oscillation damping 0 • Signal asymmetry •...
  • Page 181 Proline Promass E 300 HART Technical data Pulse/pause ratio Assignable measured • Mass flow variables • Volume flow • Corrected volume flow • Density • Reference density • Temperature  The range of options increases if the measuring device has one or more application packages.
  • Page 182 Technical data Proline Promass E 300 HART Current output 0/4 to 20 mA 4 to 20 mA Failure mode Choose from: • 4 to 20 mA in accordance with NAMUR recommendation NE 43 • 4 to 20 mA in accordance with US •...
  • Page 183: Power Supply

    Proline Promass E 300 HART Technical data Interface/protocol • Via digital communication: HART protocol • Via service interface • CDI-RJ45 service interface • WLAN interface Plain text display With information on cause and remedial measures Web browser Plain text display...
  • Page 184: Performance Characteristics

    Technical data Proline Promass E 300 HART Power consumption Transmitter Max. 10 W (active power) switch-on current Max. 36 A (<5 ms) as per NAMUR Recommendation NE 21 Current consumption Transmitter • Max. 400 mA (24 V) • Max. 200 mA (110 V, 50/60 Hz; 230 V, 50/60 Hz) Power supply failure •...
  • Page 185 Proline Promass E 300 HART Technical data Mass flow (gases) ±0.50 % o.r. Density (liquids) Under reference conditions Standard density calibration [g/cm³] [g/cm³] ±0.0005 ±0.002 Temperature ±0.5 °C ± 0.005 · T °C (±0.9 °F ± 0.003 · (T – 32) °F)
  • Page 186 Technical data Proline Promass E 300 HART 1:10 1:20 1:50 1:100 1:500 [inch] [lb/min] [lb/min] [lb/min] [lb/min] [lb/min] [lb/min] 2 573 257.3 128.7 51.46 25.73 5.146 6 615 661.5 330.8 132.3 66.15 13.23 Accuracy of outputs The outputs have the following base accuracy specifications.
  • Page 187 Proline Promass E 300 HART Technical data o.f.s. = of full scale value When there is a difference between the temperature for zero point adjustment and the process temperature, the additional measured error of the sensor is typically ±0.0002 % o.f.s./°C (±0.0001 % o.
  • Page 188: Installation

    Technical data Proline Promass E 300 HART MeasValue = measured value; ZeroPoint = zero point stability Calculation of the maximum measured error as a function of the flow rate Flow rate Maximum measured error in % o.r. ZeroPoint ⋅ ± BaseAccu ³...
  • Page 189: Process

    Proline Promass E 300 HART Technical data Storage temperature –50 to +80 °C (–58 to +176 °F) Climate class DIN EN 60068-2-38 (test Z/AD) Degree of protection Measuring device • As standard: IP66/67, type 4X enclosure • When housing is open: IP20, type 1 enclosure •...
  • Page 190 Technical data Proline Promass E 300 HART Dependency of ambient temperature on medium temperature A0031121  38 Exemplary representation, values in the table below. Ambient temperature range Medium temperature Maximum permitted medium temperature T at T = 60 °C (140 °F); higher medium temperatures T...
  • Page 191: 16.10 Mechanical Construction

    Proline Promass E 300 HART Technical data If the device is fitted with a rupture disk (order code for "Sensor option", option CA "Rupture disk"), the rupture disk trigger pressure is decisive . The sensor housing burst pressure refers to a typical internal pressure which is reached prior to mechanical failure of the sensor housing and which was determined during type testing.
  • Page 192 Technical data Proline Promass E 300 HART Weight All values (weight exclusive of packaging material) refer to devices with EN/DIN PN 40 flanges. Weight specifications including transmitter as per order code for "Housing", option A "Aluminum, coated". Different values due to different transmitter versions: •...
  • Page 193 Proline Promass E 300 HART Technical data Cable entries/cable glands A0020640  39 Possible cable entries/cable glands Female thread M20 × 1.5 Cable gland M20 × 1.5 Adapter for cable entry with female thread G ½" or NPT ½" Order code for "Housing", option A "Aluminum, coated"...
  • Page 194: 16.11 Human Interface

    Technical data Proline Promass E 300 HART Seals Welded process connections without internal seals Accessories Protective cover Stainless steel, 1.4404 (316L) External WLAN antenna • Antenna: ASA plastic (acrylic ester-styrene-acrylonitrile) and nickel-plated brass • Adapter: Stainless steel and nickel-plated brass •...
  • Page 195 Proline Promass E 300 HART Technical data Local operation Via display module Equipment: • Order code for "Display; operation", option F "4-line, illuminated, graphic display; touch control" • Order code for "Display; operation", option G "4-line, illuminated, graphic display; touch control + WLAN"...
  • Page 196 Technical data Proline Promass E 300 HART A0026786  41 Operation via remote display and operating module DKX001 Display and operating elements The display and operating elements correspond to those of the display module →  195. Housing material The housing material of the display and operating module DKX001 depends on the choice of transmitter housing material.
  • Page 197 Proline Promass E 300 HART Technical data Supported operating Operating unit Interface Additional information tools FieldCare SFE500 Notebook, PC or tablet • CDI-RJ45 service →  172 with Microsoft Windows interface system • WLAN interface • Fieldbus protocol Device Xpert...
  • Page 198 Technical data Proline Promass E 300 HART HistoROM The measuring device features HistoROM data management. HistoROM data management data management comprises both the storage and import/export of key device and process data, making operation and servicing far more reliable, secure and efficient.
  • Page 199: 16.12 Certificates And Approvals

    The device meets the legal requirements of the applicable EU Directives. These are listed in the corresponding EU Declaration of Conformity along with the standards applied. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. RCM-tick symbol The measuring system meets the EMC requirements of the "Australian Communications...
  • Page 200 • With the identification PED/G1/x (x = category) on the sensor nameplate, Directive Endress+Hauser confirms conformity with the "Essential Safety Requirements" specified in Appendix I of the Pressure Equipment Directive 2014/68/EU. • Devices not bearing this marking (PED) are designed and manufactured according to good engineering practice.
  • Page 201: 16.13 Application Packages

    The application packages can be ordered with the device or subsequently from Endress+Hauser. Detailed information on the order code in question is available from your local Endress+Hauser sales center or on the product page of the Endress+Hauser website: www.endress.com.
  • Page 202 Technical data Proline Promass E 300 HART Diagnostics functions Package Description Extended HistoROM Comprises extended functions concerning the event log and the activation of the measured value memory. Event log: Memory volume is extended from 20 message entries (standard version) to up to 100 entries.
  • Page 203: 16.14 Accessories

    For an overview of the scope of the associated Technical Documentation, refer to the following: • W@M Device Viewer (www.endress.com/deviceviewer): Enter the serial number from nameplate • Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the 2D matrix code (QR code) on the nameplate Standard documentation Brief Operating Instructions...
  • Page 204 Technical data Proline Promass E 300 HART Contents Documentation code EAC Ex nA XA01657D JPN Ex d XA01778D Remote display and operating module DKX001 Contents Documentation code ATEX/IECEx Ex i XA01494D ATEX/IECEx Ex ec XA01498D cCSAus IS XA01499D cCSAus Ex nA...
  • Page 205: Index

    Proline Promass E 300 HART Index Index 0 … 9 Connection tools ......30 Context menu 3-A approval .
  • Page 206 Index Proline Promass E 300 HART In the navigation view ..... 47 Field of application Display values Residual risks ......11 For locking status .
  • Page 207 Proline Promass E 300 HART Index Installation ....... . 22...
  • Page 208 Index Proline Promass E 300 HART Current output ......86 Reading measured values ....131 Current output (Wizard) .
  • Page 209 Proline Promass E 300 HART Index WLAN ....... . 120 Surface roughness .
  • Page 210 Index Proline Promass E 300 HART User interface Current diagnostic event ....157 Previous diagnostic event ....157 User roles .
  • Page 212 *71505952* 71505952 www.addresses.endress.com...