Installation

Installation

Shaft and Impeller Size

Flange-mounted and quick-clamp flange mounted
agitators need shafts and blades. See below
to determine the length of the shaft and the
recommended impeller diameter.
Table 3 Recommended Impeller Diameter*
Impeller
Inside Tank
Kit
Diameter "T"
Number
17N704
12" (30 cm) or less
12" (30 cm) to
17N708
22" (56 cm)
22" to 36"
17N712
(56 to 91.5 cm)
*Recommended impeller blade diameter is generally
determined by taking the inside dimension of the
tank, drum, or vessel (T in Figure 1) and multiplying
by 0.35.
**Speed is limited by material viscosity and
tank diameter for 12" (30 cm) impeller. See
Finding the Proper Agitator Speed, page 9
To determine the shaft length ("A" in Table 4):
1. Find the distance from the bottom of the tank up
1/2 the impeller diameter (i.e., 2", 4", or 6") (See
0.5 D in Figure 1 ).
2. From that point, measure to the lid mounting
surface (L).
3. Add measurement in step 2 (L) to the length of
the bearing housing (5" or 127 mm).
Example: Shaft length "A" = L + 5 inches (127 mm).
6
Stainless Steel
Impeller Diameter
"D"
4" (10 cm)
8" (20 cm)
12" (30 cm)**
.
NOTE: Round each measurement up or down to
nearest shaft length in Table 4.
Figure 1 Measure for Shaft Length
Table 4 Shaft Length Part Numbers
Shaft
Length "A"
Part No.
in (cm)
17P005
54 (137)
17P006
52 (132)
17P007
50 (127)
17P008
48 (122)
17P009
46 (117)
17P010
44 (112)
17P011
42 (107)
17P012
40 (101)
17P013
38 (97)
17P014
36 (91)
Part No.
Length "A"
in (cm)
17P015
34 (86)
17P016
32 (81)
17P017
30 (76)
17P018
28 (71)
17P019
26 (66)
17P020
24 (61)
17P021
22 (56)
17P022
20 (51)
17P023
18 (46 cm)
3A4553D