Gsm/Edge Base Station Bit Error Rate Test [Bert] - Agilent Technologies E4438C Datasheet

Esg vector signal generator
Hide thumbs Also See for E4438C:
Table of Contents

Advertisement

Specifications for Signal Personality Characteristics
GSM/EDGE base station bit error
rate test [BERT]
[Option 300]
28
This is a system of two instruments; an ESG with Option 300, and a VSA with
Option 300. Both are required. Option 300 for the ESG requires Option 601 or 602, the
TDMA personalities [Option 402], and the UN7 BER board. The VSA functions as an
IF downconverter. It may be used simultaneously to make transmitter measurements
on the loop back signal.
GSM BTS test only
E4406A VSA series transmitter tester with Options BAH
[GSM measurement personality] and Option 300 [321.4 MHz output].
GSM/EDGE BTS test
E4406A VSA series transmitter tester with Option 202 [GSM and EDGE
measurement personality] and Option 300 [321.4 MHz output].
Test technique
Supported systems
GSM 400
GSM 850
GSM 900 [P-GSM]
DCS 1800
PCS 1900
E-GSM [extended]
Minimum power level
Maximum power level
Power level accuracy
Relative power level
Timeslot under test
Timeslots tested
Encryption
Measurement triggers
Measurement indication
BCH sync
TCH sync
Threshold
RF loopback
–136 dBm [ESG minimum]
+13 dBm [option dependent]
±0.5 dB [23° ± 5 °C] [power and frequency dependent]
0 to ±130 dB relative to timeslot under test.
[Limited only by output power range of the ESG.]
0 to 7
A single timeslot is tested at one time.
[No frequency hopping.]
None
Immediate, trigger key, external, remote
[LAN, GPIB, RS-232]
Pass/fail
BCH signal from the BTS is used to determine TCH
frame and multi-frame location.
The idle frame [no RF] in the TCH signal itself is used to
determine the TCH multi-frame location and so generate
the multi-frame sync signal.
Termination of measurement when error count exceeds
user-specified threshold.

Advertisement

Table of Contents
loading