3. DSP / ENCODER
3-1. Initial Setting
1. Set the Camera recorder SW setting as shown
below.
AUTO W/B BAL
SHUTTER
GAIN
OUTPUT
WHITE BAL
2. Connect the cables as shown below with the
camera recorder and the EVR power OFF.
A J - D 6 1 0 W B
<Note>
The SCH of the signal generator should be 0
!
degrees.
!
Turn ON the EVR, then turn ON the camera
recorder.
!
Set the MENU SW to SET while pressing [SHIFT],
[+], and [-] together on the operation panel.
!
Change the PAGE and open the SERVICE ADJ
Menu, then set the ECU CONNECT to EVR. After
setting close the MENU.
!
Execute the CAM_TOOL.EXE.
(Refer to ELE-1 <Preparation for Adjustment>)
: OFF
: OFF
: L
: BAR
: PRE
3-2. AD REF Voltage Confirmation
BOARD
DSP MAIN
TP
TP4
M. EQ.
DVM
SPEC.
D C = 2 V + / -0 . 1 V
1. Confirm the DC Voltage at TP4 is in the
specification.
<MEMO>