Fan Motor / Fan Rotor
Step
4
Loosen the screw of the
fan rotor.
5
Remove the fan motor.
6
Remove the fan rotor.
26
Procedure
Fan rotor
(R9648)
When reassembling the fan
motor and the fan rotor,
provide as much as 5 mm
(0.2 inch) of play between
the side face of the rotor and
the bottom frame.
Fan motor
Side face of rotor
5 mm (0.2 inch)
(R9583)
(R9584)
(1) Insert the fan motor with
approx. 5 mm (0.2 inch) left.
(2) Tighten the screw until it
stops. Then give the screw
one more turn.
(3) Rotate the fan rotor and
confirm the fan motor and
the fan rotor are installed
appropriately.
(4) Tighten the screw
completely if appropriate.
(5) If not appropriate, go back to
(1).