Si041352EB
Step
2. Remove the
INTELLIGENT EYE
sensor PCB.
1
Unfasten the 4 hooks
and remove the
INTELLIGENT EYE
sensor ASSY.
2
Remove the sensor
from the shield plate.
3
Remove the shield
plate by unfastening the
2 hooks.
4
Disconnect the
connector [S36].
5
Remove the
INTELLIGENT EYE
sensor PCB.
3. Remove the display PCB.
1
Unfasten the 4 hooks
and remove the display
PCB.
Removal Procedure
Procedure
Hook
Sensor
Shield plate
[S36]
Hook
INTELLIGENT EYE
sensor PCB
Shield plate (rear)
Display PCB
Some models do not have
the INTELLIGENT EYE
sensor PCB.
Hook
INTELLIGENT EYE
sensor ASSY
(R9523)
When reassembling, set the
sensor at the position where
it clicks. Otherwise, the
sensor is not completely set.
(R9525)
[S36]: to control PCB
(R18892)
(R9528)
PCBs
Points
11