Fan Motor (Without Removing Indoor Heat Exchanger) - Daikin FTKM33NV2S Service Manual

6.0/7.0/7.1/8.0/8.5/9.0/9.5 kw class 28000/33000 btu/h class
Hide thumbs Also See for FTKM33NV2S:
Table of Contents

Advertisement

Si041352EB
7. Fan Motor (Without Removing Indoor Heat
Exchanger)
Warning
Step
1
Loosen the screw of the
fan motor from the air
outlet.
2
Remove the screw of
the fan motor fixing
plate (upper).
3
Unfasten the hook at
the front and remove
the fan motor fixing
plate (upper).
4
Release the harness
from the hook, and
remove the screw of the
fan motor fixing plate
(lower).
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Fan motor fixing plate (upper)

Fan Motor (Without Removing Indoor Heat Exchanger)

(R18722)
(R17238)
(R18721)
Hook
Fan motor fixing plate
(lower)
(R22256)
Points
21