Installation - ADC PAIRGAIN HiGain HDSL2 Manual

Hide thumbs Also See for PAIRGAIN HiGain HDSL2:
Table of Contents

Advertisement

152-231-115-03, Revision 03
I
NSTALLATION
Upon receipt of the equipment, inspect the contents for signs of damage. If the equipment has
been damaged in transit, immediately report the extent of damage to the transportation
company and to ADC.
When installing an H2TU-C in a chassis, be sure to wear an antistatic wrist strap. Avoid touching
components on the circuit board.
To comply with the intrabuilding wiring requirements of GR-1089 CORE, Section 4.5.9, the
shields of the ABAM-type cables that connect the H2TU-C-231 List 1E DSX-1 output ports to the
cross-connect panel must be grounded at both ends.
1
Align the H2TU-C with the enclosure slot guides and slide the unit in. Push the unit back until it touches the
backplane card-edge connector and the retaining latch on the front panel opens.
2
Place your thumbs on the front panel and push the H2TU-C into the card-edge connector until the retaining
latch closes. This indicates that the card is properly seated.
H2TU-C-231 List 1E
Figure 3. Installing the H2TU-C-231List 1E into a Shelf
April 21, 2000

Installation

9