H2Tu-R Ds1 Alarm History Screen - ADC PAIRGAIN HiGain HDSL2 Manual

Hide thumbs Also See for PAIRGAIN HiGain HDSL2:
Table of Contents

Advertisement

152-231-115-03, Revision 03
Monitor
Performance
------------------------------------------------------------------------------
Alarm
RLOS
RAIS
RAI
TX RAI-CI
PRM-NE
PRM-FE
DBER
------------------------------------------------------------------------------
Press <Space> to cycle through
choices and <Enter> to view
ID: xxxx--xxxx--xxxx--xxxx
Screen Alarm
Front-panel Alarm Description
H2TU-C DS1 ALARMS (see
(a)
LLOS
LLOS
LAIS
LAIS
DBER
DBER
H2TU-R DS1 ALARMS (see
(a)
RLOS
RLOS
RAIS
RAIS
RAI
RRAI
TX RAI-CI
TRCI
PRM-NE
PRMN
PRM-FE
PRMF
DBER
DBER
(a) This is a DS1-specific alarm that also issues a minor alarm (sent to the management unit or the backplane), if enabled.
(b) AIS-CI is a modified AIS alarm pattern. Equipment not suited to detect AIS-CI still detects this signal as an AIS. AIS-CI is sent
toward the network indicating that an LOS (RLOS) or AIS (RAIS) has been received from the CPE.
H2TU-C-231 List 1E
Event Log
Config
H2TU-R DS-1 Alarm History
First
04/05/00 00:00
04/05/00 00:37
Press: C(l)ear Alarm History
Interface
Statistics :
04/15/00 12:30:01
Figure 21. H2TU-R DS1 Alarm History Screen
Table 17. DS1 Alarm Descriptions
Figure 20 on page
40)
Local Loss of Signal—Loss of the H2TU-C DSX-1 input signal.
Local Alarm Indication Signal—Indicates an AIS (all ones) pattern is being transmitted
from the local DS1 output port. The ALMP option determines whether AIS (default) or
LOS is sent towards the CPE.
Bit Error Rate—The DS1 BER has exceeded the built-in 24-hour threshold limits of
approximately 10
Figure
21)
Remote Loss of Signal— Loss of the H2TU-R DS1 input signal.
Remote Alarm Indication Signal—Indicates an AIS (all ones) pattern is being received at
the H2TU-R DS1 input port. By default (see
towards the network.
Remote RAI - Remote Alarm Indication at the H2TU-R—Indicates an RAI alarm (yellow)
from the CPE with errors from the line unit or network.
Transmit RAI-CI - Remote Alarm Indication at the H2TU-R—Upon reception of an RAI
(yellow alarm) from the CPE, the H2TU-R sends a RAI-CI towards the network if the
network signal received at the H2TU-R is clear. If the network signal is impaired (LOS, AIS
or LOF), then the RAI is passed on to the network unaltered. This is applicable to SF or
ESF framing. In an all SF environment, RACI must be enabled to convert SF RAI to SF
RAI-CI.
Performance Report Monitoring - Near End—The count of the PRM-NE register at the
H2TU-R exceeds the 10
Performance Report Monitoring - Far End—The count of the PRM-FE register at the
H2TU-R exceeds the 10
Bit Error Rate—The DS1 BER has exceeded the built-in 24-hour threshold limits of
approximately 10
Inventory
Rlogon
Last
04/11/00 00:45
04/11/00 00:45
: H2TU-R DS-1
Alarm History
H2TU-C
-6
.
Figure 24 on page
-6
BER threshold at 648 events since 12:00:00 AM.
-6
BER threshold at 648 events since 12:00:00 AM.
-6
.
April 21, 2000
Monitoring System Activity and Performance
Help
Status
Count
ALARM
12
OK
0
OK
0
OK
0
OK
0
OK
0
OK
7
System: Alarm
(b)
47) AIS-CI
is sent