Wear an antistatic wrist strap when installing the H2TU-R.
Avoid touching components on the circuit board.
1
Configure the H2TU-R for line or local power, as follows:
For line power, place a jumper on pins 2 and 3 of P2 and P3.
For local power, place a jumper on pins 1and 2 of P2 and P3.
2
Check the setting of the Sealing Current (SCURR) jumper (P1). The default
setting is disabled (jumper on pins 2 and 3). If the H2TU-R is locally powered
and your application requires sealing current, place a jumper on pins 1 and 2.
3
Align the H2TU-R with the enclosure slot guides and slide the unit in. Push the
unit back until it touches the backplane card-edge connector.
4
Place your thumbs on the front panel and push the H2TU-R into the card-edge
connector.