Marantz SR5012 Service Manual page 133

Av surround receiver
Hide thumbs Also See for SR5012:
Table of Contents

Advertisement

1.4. Error display
See the table below for descriptions of the displayed errors and countermeasures for these.
If multiple errors occur, only one item is displayed.
The priority order is w, e, r, t, y, q.
Condition
States
The model name, brand name and region information
written in the firmware are compared to the region
settings in the PCB. This error is displayed if the infor-
q
mation does not match.
Firm Check
NG
" ▲ " is displayed as the first character if the firmware
is not correct (see the illustrations on the right).
An error occurs in Loop back Test of the DDR memory
which is performed during the initial setting of i/p
Scaler(ADV8003).
w
IP SCALER NG
During the initial setting of i/p Scaler ( ADV8003 ) ,
there is not the reply of the Loop back Test result of
the DDR memory .
If the Main CPU version is not supported by the GUI
e
Serial Flash (ADV8003),
GUI Serial
" ▼ " is displayed as the first character of the GUI
Flash NG
firmware version.
Display
L1
FIRM
L2
ERROR
L3
L1
M:*****
L2
********
L3
BL-**.**
L1
DSP
L2
********
L3
L1
A.PLD
L2
L3
**.**
L1
V.PLD
L2
L3
**.**
L1
GUI
L2
L3
**.**
L1
IP
L2
SCALER
L3
ERR 01
L3
ERR 02
L1
GUI VER.
L2
ERROR
L3
133
TROUBLE SHOOTING
• Check the resistor for setting the
region(R1524 / 1525 DIGITAL PCB).
• Write the firmware for the correct
region.
• Check the circuits around the IP
SCALER (U1026, DIGITAL PCB) and
DDR2 (U1028/1029).
If there appear to be no problems,
U1026 or U1028/1029 is faulty.
• Check the firmware version.

Advertisement

Table of Contents
loading

Table of Contents