3-7. Error Code H1-04 failure detection procedure
Checking device.
[U1103 :
TMDS261B]
Check item(29).
Replace [U1103] with a new device.
Recheck from
check item (1)
Does Error Code H1-04 continue?
YES
Replace the PCB.
NO
Recheck from
check item (2).
3-8. Error Code H1-05 failure detection procedure
Checking device.
[U2022 :
ADV7180]
Check item(30).
Replace [U2022] with a new device.
Recheck from
check item (1)
Does Error Code H1-05 continue?
YES
Replace the PCB.
108
NO
Recheck from
check item (2).