3-Axis Linear Interpolation Control - Mitsubishi Electric MELSEC-Q Series User Manual

Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

9.2.4 3-axis linear interpolation control

Example
When the start point address (current stop position) is (1000, 2000, 1000) and the end point address
(positioning address) is (4000, 8000, 4000), positioning is carried out as follows.
Axis 3 movement amount
(4000-1000=3000)
In "3-axis linear interpolation control" ("[Da.2] Control method" = ABS linear 3, INC
linear 3), three motors are used to carry out position control in a linear path while
carrying out interpolation for the axis directions set in each axis.
(Refer to Section 9.1.6 "Interpolation control" for details on interpolation control.)
[1] 3-axis linear interpolation control (ABS linear 3)
Operation chart
In the absolute system 3-axis linear interpolation control, the designated 3 axes
are used. Linear interpolation positioning is carried out from the current stop
position (start point address) to the address (end point address) set in the "[Da.6]
Positioning address/movement amount".
Forward direction (Z axis)
Reverse direction
Axis 3
4000
Forward direction
End point address (X
(Y axis)
X axis movement amount
Reverse direction Reverse direction
End point address
(positioning address)
Axis 2
8000
2000
1000
1000
4000
0
9 - 37
Chapter 9 Major Positioning Control
,Y
Z
)
2
2,
2
(Positioning address)
Movement by linear interpolation
of the X axis, Y axis and Z axis
Y axis movement amount
Start point address (X
(Current stop position)
Forward direction (X axis)
Axis 2 movement amount (8000-2000=6000)
Start point address
(current stop position)
Axis 1
Axis 1 movement amount
(4000-1000=3000)
,Y
,Z
)
1
1
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-qd77gf4Melsec-qd77gf8Melsec-qd77gf16

Table of Contents